V2 SPA CITY6 Manual De Instruccion página 34

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Photocell 2 input
This menu allows enabling the input for type 2 photocells, that is to say,
photocells non active during the opening phase (see paragraph "Installation").
no
input disabled (ignored by the control unit).
No jumper with the common is required.
CF.CH
input enabled even at standstill gate too: the opening
movement does not start if photocell is interrupted.
CH
input enabled for the closing phase only
Warning: if you select this option, you must disable photocell test.
Test of safety devices
In order to achieve a safer operation for the user, the unit performs a safety
devices operational test, before a normal working cycle.
If no operational faults are found, the gate starts moving. Otherwise, it will
stand still and the flashing light will stay onfor 5 sec. The whole test cycle lasts
less than one second.
no
function not active
Foto
test enabled only for photocells
CoSt
test enabled only for safety edges
Ft.Co
test enabled either for photocells or for safety edges
WARNING:
• If you use conductive rubber edges, DO NOT activate the functioning test for
the edge.
• The test on edges with contact normally shut is only possible if a power unit
specifically for this use has been installed.
• The Test of safety devices should be working in order to grant more safety
during installation and programming.
Safety ribbon 1 input
This menu allows enabling the input for type 1 safety ribbon, that is to say,
fixed ribbons (see paragraph "Installation").
no
Input disabled (ignored by the control unit).
No jumper with the common is required.
StAn
input enabled for standard safety ribbons with n.c. contact
rESi
input enabled for conductive rubber safety ribbons
with nominal resistance 8,2 kohm.
Safety ribbon 2 input
This menu allows enabling the input for type 2 safety ribbon, that is to say
mobile ribbons (see paragraph "Installation").
no
Input disabled (ignored by the control unit).
No jumper with the common is required.
StAn
input enabled for standard safety ribbons with n.c. contact
rESi
input enabled for conductive rubber safety ribbons
with nominal resistance 8,2 kohm.
30

Publicidad

Tabla de contenido
loading

Tabla de contenido