DISPLAY DATA
DESCRIPTION
t.AP
0.0" ÷ 2.0'
Gate opening time
t.APP
0.0" ÷ t.AP1
Opening time of pedestrian gate
t.Ch
0.0" ÷ 2.0'
Gate closing time
t.ChP
0.0" ÷ t.Ch
Closing time of pedestrian gate
t.PrE
0.5" ÷ 2.0'
Pre-flashing time
no
- Pre-flashing disabled (it corresponds to 0)
St.AP
Start in opening
no
- Start command is not available
ChiU
- Command close gate
PAUS
- Stop the gate and goes in pause
St.Ch
Start in closing
Stop
- Start command stop the gate
APEr
- Start command open the gate
St.PA
Start in pause
no
- Start command is not available
ChiU
- Start command closes the gate
SPAP
Pedestrian in opening
no
- Pedestrian start command is not available
ChiU
- Pedestrian start command closes the gate
PAUS
- Gate goes in pause
Ch.AU
Automatic closing
no
- The gate closes after the setup time)
0.5"÷ 20.0'
- The automatic closing is not active (it corresponds to 0)
Ch.tr
Closing after passage
no
- Closing after passage disabled
0.5"÷ 20.0'
- Gate stop for a time to be set between 0.5" to 20'
PA.tr
no/Si
Pause after transit
LP.PA
no/Si
Flashlight in pause
St.rt
Operation modes
AP.CH
- Separated opening and closing commands
PrES
- Manned operation
oroL
- Timer operation
StAn
- Start inputs from terminal board are disabled
no
- Standard operation
FrEn
no/Si
Brake function
StoP
STOP input
ProS
- STOP command stops the gate: pressing the START command gate continues the
invE
- STOP command stops the gate: START command starts moving in the opposite

City6 FUNCTION TABLE

motion
direction
34
MEMO
DEFAULT
DATA
15.0"
6.0"
16.0"
7.0"
1.0"
PAUS
StoP
ChiU
PAUS
no
no
no
no
StAn
no
ProS

Publicidad