CARE AND CLEANING
4. Attach grille (B) by pinching the mounting springs and inserting
them into the narrow rectangular slots in the fan housing (A).
Turn on power source.Test the unit.
TROUBLESHOOTING
PROBLEM
The fan seems louder than it
should.
The fan has an abnormal
sound or vibration.
The fan is not clearing
humidity from the room.
The fan keeps running even
though the humidity level is
lower than 60% RH.
NOTE: Our sensor tolerance
is +/-10% RH.
LIMITED 3-YEAR WARRANTY
If the fan fails due to a defect in materials or workmanship at any time during the first three (3) years of ownership, the manufacturer will
replace it free of charge, postage-paid at their option. This warranty does not cover products that have been abused, altered, damaged,
misused, cut or worn. This warranty does not cover use in commercial applications. Use only manufacturer-supplied genuine warranty
repair replacement parts to repair this fan. Use of non-genuine repair parts will void your warranty. The manufacturer DISCLAIMS all
other implied or express warranties including all warranties of merchantability and/or fitness for a particular purpose. As some states do
not allow exclusions or limitations on an implied warranty, the above exclusions and limitations may not apply. This warranty gives
you specific legal rights, and you may have other rights that vary from state to state.
This warranty is limited to the replacement of defective parts only. Labor charges and/or damage incurred during installation, repair,
replacement as well as incidental and consequential damages connected with the above are excluded. Any damage to this product
as a result of neglect, misuse, accident, improper installation or use other than the purpose SHALL VOID THIS WARRANTY.
Shipping costs for return product as part of a claim on the warranty must be paid for by the customer. Inquiries regarding warranty
claims can be directed to 1-877-319-3757, 7:30 a.m. - 4:30 p.m., CST, Monday - Friday.
POSSIBLE CAUSE
The CFM is too great for the space.
The damper is damaged or not working properly.
The bend in the duct is too close to the fan dis-
charge.
The fan discharge is reduced to fit a smaller duct.
The fan body is not attached securely.
The fan body is not attached securely.
The grille is not attached securely.
The circular duct is not secured to the duct
connector.
There is insufficient airflow intake in the room.
There is insufficient CFM.
NOTE: Using a tissue is not the correct method for
determining if the fan is operating properly. If the fan
clears steam from the room within approximately 15
minutes of completing your shower, then the fan is
operating properly.
Outdoor humidity is back drafting into the fan.
The fan is operating in manual mode.
4
SOLUTION
Be sure the CFM rating on the fan matches the
square footage of your room.
Check the damper to ensure it is opening and closing
properly. If the damper has become damaged, please
call Customer Service.
Be sure you do not have any sharp bends in the duct
within 18 in. of the fan discharge.
Use the recommended size ducting to reduce fan
noise.
Be sure the fan housing is securely attached to the
ceiling joists.
Be sure the fan housing is securely attached to the
ceiling joists or wall studs.
Be sure the grille is pushed upward gently until it is
firmly attached to the fan housing.
Be sure the duct tape or clamp is secured for an
airtight connection.
Be sure a door or window is slightly ajar or open to
allow airflow. The fan is not able to draw air out of the
room without enough airflow.
Be sure the CFM rating of the fan matches the
square footage of your room.
Continue to let fan run since it is good to keep venting
the house and the electric cost is minimal (estimated
at less than $10 per year).
Verify the humidity sensing function has been selected
on the wall switch. The humidity sensor icon will be
illuminated when humidity sensing mode is turned on.
10