lead to one or more problems occurring.
3. Materials with voids are more susceptible to water seepage, leading to erosion. Water ingress may also cause the soil to
building foundations and normally leads to the structure requiring underpinning.
Compaction increases the density of the material and therefore increases its load bearing capacity. Reduces air voids and therefore
reduces the risk of subsidence, expansion and contraction, due to ingress of water.
Honda Petrol Engine
1.
Open the fuel tap by moving the fuel ON / OFF lever fully to the right.
2.
If starting the engine from cold, set the choke ON by moving the choke lever fully
to the left. If restarting a warm engine, the choke is usually not required, however, if
the engine has cooled to a degree, partial choke may be required.
3.
Turn the engine ON / OFF switch clockwise to the 'I' position.
4.
Set the throttle to the idle position by moving the throttle lever fully to the right. Do
not start the engine on full throttle, as the compactor will vibrate as soon as the
engine starts.
handle with the other. Pull the recoil starter until engine resistance is felt, then let
starter return.
6.
Taking care not to pull the starter's rope fully out, pull the starter handle briskly.
10. To stop the engine, set the throttle to idle and turn the engine ON / OFF switch anticlockwise to the '0' position.
11. Turn the fuel off.
Hatz Diesel Engine
1. Turn ON the fuel by moving the fuel ON/OFF lever fully to the right.
2. Set the engine speed control to start.
the other. Pull the handle until engine resistance is felt, then let the starter return.
4. Taking care not to pull the starter's rope fully out, pull the starter handle briskly with both
hands.
6. If the engine fails to start after several attempts, Follow the troubleshooting guide.
7. To stop the engine, set the throttle control to idle, then press and hold the red stop button
until the engine stops.
Reasons For Compaction
Start And Stop Procedure
OFF position by moving it to the right.