After having carried out the various connections and having supplied voltage, all the LEDS
are switched off.
The motor opens and closes, but it has no strength and moves slowly.
The gate opens but does not close after the time set.
The gate does not open or close by activating the various START, RADIO, OPEN and CLOSE
buttons.
The electric lock does not work.
Impact sensor intervenes during the movement
The buzzer emits 2 long tones and the gate does not move
The remote control does not work. Led DL12 lit red
ACCESSORIES -
FOUNDATION BOX FOR DUKE 24V 110°
INOX
RELEASE WITH DIN CYLINDER
RELEASE WITH HANDLE
FAULT
For the connections and the technical data of the optional equipments follow the relevant handbooks.
code ACG8435
code ACG8437I
code ACG2120
code ACG2130
On the board there are resettable fuses which intervene in the event of a short circuit,
interrupting the output assigned to them.
In the event of troubleshooting, it is advisable to disconnect all the removable
connectors and insert them one at a time in order to more easily identify the cause
of the fault.
Check fuses F1, F2.
If the fuse is blown, use only a suitable replacement.
F1 T 2A
TRANSFORMER PROTECTION FUSE (on the outside of the B2D 24V board)
F2 T 8A
MOTOR PROTECTION FUSE
Check trimmers RUN and LOW SP adjustment.
Make sure that the TCA trimmer is activated with LED DL11 ON.
B.I.O. contact always on => check the status of the clock connected to B.I.O..
Photocells Auto-test failed => check the connections between the control panel and the
photocells.
Stop, Edge or Photocell with DIP 4 OFF contact fault => Fix or replace the faulty contact.
Photocells Auto-test failed => check the connections between the control panel and the
photocells.
Ensure to have enabled DIP 8 at ON.
Check the cable.
Turn the SENS trimmer clockwise
Safety edge with 8,2 KΩ resistor. Remove the resistor or configure the EDGE input via the
RIB GATE app
Lack of radio module in connector J6 or faulty radio module.
FOUNDATION BOX FOR DUKE 24V 180°
INOX
RELEASE WITH TRIANGLE KEY
FIT SLIM
PHOTOCELLS FOR THE WALL-INSTALLATION
PAIR OF COLUMNS FOR FIT SLIM
42
SOLUTION
code ACG8436
code ACG8438I
code ACG2125
code ACG8032B
code ACG8065

Publicidad

loading

Este manual también es adecuado para:

Abb2060Abb2061Ac08072