P SERIES 6X4 WARNING LIGHT
OVER-VOLTAGE PROTECTION
When an over-voltage condition is detected, the module will flash an over-voltage warning pattern of 50mS ON/950mS OFF to alert of the over-voltage condition and protect the electronics from damage due to heat/voltage.
THERMAL COMPENSATION PROTECTION
The LED module is designed to provide maximum power output while providing protection to the electronic components by reducing the output power at extreme temperatures.
SYNC 2
Synchronizing the flashing of multiple light modules is accomplished by connecting the Green wires of different light modules together. Up to 24 light modules can be connected for synchronized flashing. All light module flash patterns must be
set to the same flash pattern # to ensure proper operation. Refer to the Sequence Type section in Set-Up Table (page 8) to setup light modules to flash in alternate or simultaneous flash pattern. NOTE: Will NOT work with non-Sync 2 products
such as Ghost, LED3, and 4 wire Intersector. WILL WORK with Sync 2 products mPOWER, nFORCE Secondary Lights, nFORCE FIT and 5 wire Intersector Lights.
FLASH PATTERNS
SINGLE
PATTERN #
DUAL COLOR
COLOR
1
QUINT
2
WARP
3
INTER-CYCLE
4
DOUBLE
5
QUAD
6
POWER PULSE
7
ROAD RUNNER
8
Q-SWITCH
STEADY-BURN / ROADRUNNER
9
(SEQUENCE TYPE 1: STEADY BURN, SEQUENCE
TYPE 2: ROADRUNNER)
STEADY-BURN DRIVER TITLE 13 QUAD
10
(SEQUENCE TYPE 1: STEADY BURN, SEQUENCE
TYPE 2: TITLE 13 QUAD)
11
QUAD 2
12
DOUBLE 2
13
RANDOM 1
14
RANDOM 2
15
QUAD PULSE-POP
1.800.338.7337 / www.soundoffsignal.com
5
CERTIFICATIONS
FLASHES PER
TRI-COLOR
HIGH POWER
MINUTE
70
SAE, KKK
360
-
70
SAE, KKK
80
SAE, NFPA, KKK
180
SAE, NFPA, KKK
118
SAE, CA13*, NFPA, KKK
-
- / 118
- / 65
67
SAE, KKK
95
SAE, NFPA, KKK
-
-
75
SAE, CA13*, NFPA, KKK
CERTIFICATION
APPLICABLE COLORS
SAEJ595
Red, Amber, Blue, White, Green
CALIFORNIA TITLE 13
Red, Amber, Blue
NFPA 1901-2009
Red, Amber, Blue, White
KKK-A-1822F (JULY 2021)
Red, Amber, Blue, White, Green
WIRING AND TABLE INFORMATION
LOW POWER
SAE, KKK
NA
NA
NA
NA
SAE, KKK
SAE, NFPA, KKK
SAE, NFPA, KKK
SAE, CA13*, NFPA, KKK
NA
NA
NA
NA
NA
NA
SAE, KKK
SAE, NFPA, KKK
NA
NA
NA
NA
*CA13 AMBER is met in Low Power Only
SAE, CA13*, NFPA, KKK
*CA13 AMBER is met in Low Power Only
Lights are chassis-grounded. If you need to ground-switch the light, you must isolate the lights
metal backing, heatsink, studs and/or screws from the body of the vehicle or use a relay.
WIRE HOOK-UP TABLE
WIRE COLOR:
FUNCTION:
RED
Power (Primary)
BLACK
Ground
GREEN**
Sync2 *
WHITE to GROUND
Setup Wire (See pg. 8*)
WHITE to POWER
Function Wire
ORANGE
Power (Secondary)
** To sync multiple P Series lights, connect the Green
wire from each light together.
* Will NOT work w/ other sync products such as
Ghost, LED3, & 4 wire Intersector w/external flasher.
* Will Work with Sync 2 products mPOWER, nFORCE
Secondary Lights, nFORCE FIT and 5 wire Intersector Lights.
5
A FUSE
ORANGE
+Vdc
GREEN
Sync
WHITE
Set-up/Function
RED
+Vdc
+Vdc
5
BLACK
A FUSE
6X4 POLYCARB_WARNING 0422 REV C