Inefficient combustion on
ceramic burner
Technical
problems
If there is no ignition
Burner flame has extingui-
sh during operation
Heater is not remain alight
when pressure is released
from ignition button
general
problem
Heater could not be
FAULT FINDING CHART
Problem
Smell of gas
turned on
Problem Causes
Regulator & hose connection loose
Valve & pipe connection loose
Pipe broken
Missing piece of ceramic fireclay
Dirty gas inlets
Battery no power
Defective Spark - Plug
Defective ignitor cable
Run out of gas
Thermal element has not been
warm enough
Wing or draught has extinguished
the flame
Faulty thermocouple
Faulty magnetic valve
Wrong power setting at first process
Did not connect the gas regulator to
gas cylinder
Gas cylinder control is closed
What To Do
Use soap form for
leakage control, check
all connection system
replace defected parts
Inspect perimeter
of each plaque and
locate place where
some fireclay has been
displaced. Repair with
PYRUMA and leave
to set for Approx. 48
hours.
Please clear injectors
with Air
Change a AAA battery
Check cable of ignitor,
& replace defected
ignitor if necessary
Check spark – plug
and connections, & re-
place defected ignitor
if necessary
Change the gas bottle
Try restarting
Put the appliance out
of reach of wind and
draught, let it cool
down for a couple of
minutes and try to
restart it
Replace the faulty
thermocouple
Replace the magnetic
valve
Turn the control knob
at " START" Position
and press for 10 se-
conds, whilst press the
Piezo igniter key to lit
Connect heater to
the gas cylinder and
ensure there is not
smell, then follow the
Instruction to turn on
the heater
Please turn on the gas
cylinder control

Publicidad