SEAR STATION
BURNER IGNITION
®
Summary lighting instructions are inside the left-hand cabinet door .
m DANGER
Failure to open the lid while igniting the grill's burners, or
not waiting five minutes to allow the gas to clear if the grill
does not light, may result in an explosive flame-up which can
cause serious bodily injury or death.
The Sear Station
burner has an on or off control setting . To ignite the Sear Station
®
burner, you must first ignite the two adjacent main burners .
Adjacent Main Burner Snap Ignition
Note: Each main burner control knob snap igniter creates a spark from the igniter
electrode to the burner lighting tube. You generate the energy for the spark by pushing
in the control knob and turning it to START/HI. This will ignite each individual burner.
m WARNING: Check hose before each use of grill for nicks,
cracking, abrasions or cuts. If the hose is found to be
damaged in any way, do not use the grill. Replace using
only Weber
authorized replacement hose. Contact the
®
Customer Service Representative in your area using the
contact information on our web site.
Log onto www.weber.com.
A) Open the lid (1) .
B) Make sure all burner control knobs are turned off (2) . (Push control knob in and turn
it clockwise to ensure that it is in the OFF position .)
C) Turn on the gas supply at source (3) .
m WARNING: Do not lean over the open grill.
D) Ignite each main burner that is adjacent to the Sear Station
knob in and turn it to START/HI until you hear the igniter snap; continue to hold
control knob in for two seconds . This action will spark the igniter, the burner lighting
tube, and then main burner .
E) Check that the burner is lit by looking through the cooking grates (5) . You should see
a flame . If burner does not light on first try, push control knob in and turn it to OFF .
Repeat lighting procedure a second time .
Sear Station
Burner Lighting:
®
Ignition by an Adjacent Ignited Main Burner
burner control knob to the ON position (6) .
F) Turn Sear Station
®
G) Verify burner ignition by visual inspection of a flame (7) .
m WARNING: If ignition does not occur in five seconds, turn
burner control OFF, wait five minutes, and repeat steps F &
G, or see "SEAR STATION
instructions.
m WARNING: If the burner still does not light, turn the burner
control knob to OFF and wait five minutes to let the gas
clear before you try again or try to light with a match.
Note: See "MAINTENANCE" for burner removal and cleaning
procedure.
◆
TO EXTINGUISH
Push in and turn each burner control knob clockwise to OFF position . Turn gas supply off
at the source .
◆
SEAR STATION
(4) . Push the control
®
BURNER MANUAL IGNITION"
®
IGNITION & USAGE
®
®
1
The grills illustrated
in this Owner's Guide
may vary slightly from
the model purchased .
2
APAGADO
ARRÊTÉ
OFF
ON
5
7
2
4
6
3
6
WWW.WEBER.COM
®
21