Descargar Imprimir esta página

voestalpine bohler SABER 70 CHP Manual De Instrucciones página 39

Ocultar thumbs Ver también para bohler SABER 70 CHP:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 103
Passing one of the warning limits causes a visual signal to appear
on the control panel.
Passing one of the alarm limits causes a visual signal to appear
on the control panel and the immediate blockage of the cutting
operations.
It is possible to set start and end of cutting filters to prevent error
signals during the striking and extinction of the arc (consult the
"Set up" section - Parameters 802-803-804).
3.10 Alarms screen
Allows the intervention of an alarm to be indicated and provides
the most important indications for the solution of any problem
encountered.
1
Alarm icon
2
Alarm code
3
Alarm type
Alarm codes
E01, E02 Temperature alarm
It is advisable not to switch off the equipment while the alarm
is on; the internal fan will thus keep operating and will help to
cool the overheated parts.
E10
Power module alarm
E13
Communication alarm
E16
Communication alarm (RI)
E19
System configuration alarm
E20
Memory fault alarm
E21
Data loss alarm
E40
System power supply alarm
E45
Air pressure alarm
E47
Nozzle retaining cap guard alarm
E49
Emergency switch alarm
E78
Active maintenance alarm
(Automation and robotics)
E99
General alarm
Guard limits code
E54
Current level exceeded (Alarm)
E62
Current level exceeded (Warning)
E55
Current level exceeded (Alarm)
E63
Current level exceeded (Warning)
E56
Voltage level exceeded (Alarm)
E64
Voltage level exceeded (Warning)
E57
Voltage level exceeded (Alarm)
E65
Voltage level exceeded (Warning)
E58
Gas pressure level exceeded
E66
Gas pressure level exceeded
E59
Gas pressure level exceeded
E67
Gas pressure level exceeded
E60
Speed limit exceeded
E68
Speed limit exceeded
(Alarm)
(Warning)
(Alarm)
(Warning)
(Alarm)
(Warning)
39

Publicidad

loading