Care and Cleaning
Shut off main power supply before cleaning the product. To prolong the original appearance, clean the light fixture
with clear water and a soft, damp cloth only.
Do not use abrasive cleaners or cleaners that contain alcohol. Do not apply paints, solvents, or any other
chemicals on this light fixture. They could cause a premature deterioration of the finish and may void the warranty.
Do not spray the light fixture with a hose or power washer.
Troubleshooting
Problem
Light does not
turn ON
Light cycles
ON and OFF
continuously
Light
FLICKERS
Light stays ON
NOTE:
Photocell may have a longer delay during trouble shooting. When testing, shine
flashlight or cover the photocell and allow for up to 1 minute for the fixture to work properly.
Possible Cause
No power to the fixture
Photocell is sensing light.
Photocell light sensor
is sensing reflected light
The light fixture is wired
through an unsuitable dimmer
Photocell is in a shaded area
Photocell is faulty
Check if circuit breaker is tripped.
Confirm wall switch is ON.
Verify wiring to the fixture is correct
(turn the power off to the fixture beforehand).
Test the Photocell operation by covering it
for 10 seconds until the fixture turns ON.
Relocate light fixture away from other light
sources for Dusk to Dawn operation to
work properly.
OR place the black cap over the photocell
and use the wall switch to turn the light
fixture ON and OFF.
Replace the dimmer with a 0-10V dimming
switch or a standard ON/OFF wall switch.
Shine the flashlight into the photocell for 10
seconds. If the light turns OFF, the fixture
should be relocated to a location with
enough light in daylight hours for photocell
to work properly.
OR place the pre-installed black cap onto
the photocell and use the wall switch to
turn the light fixture ON and OFF.
If the light fixture does not turn OFF when
a flashlight is used on the photocell for
10 seconds, then the photocell may be
faulty. Please contact customer service.