The following table shows the alarms on the COMPACT screen:
COMPONENT
GENERATING
TYPE OF ALARM
THE ALARM
SYSTEM FAULT
SYSTEM FAULT
RECOVERED
ETH A
LINK FAIL
ETH B
LINK FAIL
NETWORK
ERROR
ROUTING ERROR
MAIN POWER
POWER FAIL
COMPACT version 5.0.002
COMPACT
DESCRIPTION
Firmware error
This is not an alarm; instead, it is a
system fault recovery notification
The connection to the unit's ETH A port
fails.
The connection to the unit's ETH B port
fails.
The unit does not respond to a network
ping.
COMPACT units that allow routing
communications in the system do not
operate properly.
Indicates a failure of the primary power
to the COMPACT.
RECOVERY
Restart the unit.
If
desired,
notification. To accomplish this, carry
out the following from the unit that is
sending the notification:
1. Press or to display the alarms
tab (
2. Use the navigation keys / to
view one of the alarms and press
OK.
3. Using the / keys, select the
RESET ALL FAULTS option.
4. Press OK.
If the installation does not have a
redundant network, use the Call Point
software to disable the displaying of the
Ethernet
configurations to the unit.
If the installation has a redundant
network, check the cable connection to
the ETH A port on the unit.
If the installation does not have a
redundant network, use the Call Point
software to disable the displaying of the
Ethernet
configurations to the unit.
If the installation has a redundant
network, check the cable connection to
the ETH B port on the unit.
Check the connection of the unit to the
Ethernet network. If the connection is
correct, check the network.
Check the primary power by ensuring
the COMPACT is receiving 24 VDC
through the POWER SUPPLY 1 terminal
strip (see figure 3, number 8).
R +D Department
Modular audio matrix
with IP connection
you
can
delete
this
).
Links
alarm
and
send
Links
alarm
and
send
26