COMPONENT
GENERATING
TYPE OF ALARM
THE ALARM
AUX. POWER
POWER FAIL
"UNIT NAME"
MICROPHONE
CAPSULE ERROR
ME-200B
CAPSULE ERROR
ME-200B
NOT DETECTED
"NAME OF THE
SHORT CT ERR.
CONTACT"
"NAME OF THE
OPEN CT ERR.
CONTACT"
"PERSONALISED
TEXT TO NOTIFY
AN ALARM"
S ["n"]
NOT DETECTED
(n= Number of
slave, id.)
S ["n"]
CONFIGURATION
ERROR
(n= Number of
slave, id.)
COMPACT version 5.0.002
COMPACT
DESCRIPTION
Indicates a failure of the secondary
power to the COMPACT.
Indicates a capsule error of the
microphone desk that is sending the
alarm.
Indicates a capsule error of the
microphone on the ME-200B front
module.
Module ME-200B is not detected.
A short-circuit is detected in the
connection of a contact configured to
be monitored.
An open contact is detected in the
connection of a contact configured to
be monitored.
A contact may be configured so its
activation will generate an alarm on the
screen with the desired text.
The
system
does
not
COMPACT-E unit that appears in the
configurations of the installation.
The system detects a COMPACT-E unit
that
does
not
appear
configurations of the installation.
RECOVERY
If the installation does not have a
redundant power supply, use the Call
Point software to disable the displaying
of the Power supply alarm and send
configurations to the unit.
If secondary power is available, check
that the unit is receiving 24 VDC
through the POWER SUPPLY 2 terminal
strip (see figure 3, number 9).
Check
the
microphone to the ME-200B module
(metal DIN connector).
If the COMPACT incorporates the ME-
200B module, disconnect the power
supply
and
connections between the ME-200B
module and the COMPACT.
If the COMPACT does not incorporate
an ME-200B module, disable this
functionality
configuration.
Check the connection of the contact.
If the contact must not be monitored,
modify the configuration of the contact
via the Call Point software.
Check the connection of the contact.
If the contact must not be monitored,
modify the configuration of the contact
via the Call Point software.
detect
a
Check the CAN bus connection between
the COMPACT-E unit and the COMPACT.
If the unit is not physically present,
check
the
installation in the Call Point software to
verify that a COMPACT-E unit has not
been added by error. If so, delete it.
Use the Call Point software to add the
in
the
unit to the installation tree.
or
disconnect the unit from the CAN bus