Descargar Imprimir esta página

Optimus COMPACT Manual De Instrucciones página 30

Ocultar thumbs Ver también para COMPACT:

Publicidad

Idiomas disponibles

Idiomas disponibles

COMPONENT
GENERATING
TYPE OF ALARM
THE ALARM
C ["n":"p" ]
NOT DETECTED
(n= Number of
slave, id.)
If the value is 0,
the unit is a
COMPACT)
(p= lot occupied
by the card)
C ["n":"p" ]
CONFIGURATION
ERROR
(n= Number of
slave, id.)
If the value is 0,
the unit is a
COMPACT)
(p= Slot occupied
by the card)
"ZONE NAME"
LZ LINE ERROR
"ZONE NAME"
HZ LINE ERROR
"ZONE NAME"
AMPLIFIER
ERROR
"ZONE NAME"
SHORT LINE
ERROR
"ZONE NAME"
OPEN LINE
ERROR
COMPACT version 5.0.002
COMPACT
DESCRIPTION
The unit "n" incorporates a card in slot
"p" that is not detected by the system,
although
it
does
appear
configurations of the installation.
The unit "n" incorporates a card in slot
"p" that does not appear in the
configurations of the installation.
When monitoring the speaker line of
the indicated zone, the system detects a
low impedance error.
When monitoring the speaker line of
the indicated zone, the system detects a
high impedance error.
Zone amplification error
When monitoring the speaker line of
the indicated zone, the system detects a
short-circuit in the line.
When monitoring the speaker line of
the indicated zone, the system detects
an open line error.
RECOVERY
Check that the card is physically present
and is properly inserted
in
the
or
the card is missing. From the Call Point
software, delete the card from the
installation tree.
Use the Call Point software to add the
unit to the installation tree.
or
remove the card from the COMPACT or
COMPACT-E chassis
The impedance in the speaker line has
changed. Inspect said line and check the
status of the speakers.
If the status of the line is correct, you
can adjust the monitoring of the line
and expand the tolerance margin for
detecting the error.
The impedance in the speaker line has
changed. Inspect said line and check the
status of the speakers.
If the status of the line is correct, you
can adjust the monitoring of the line
and expand the tolerance margin for
detecting the error.
Check the operation of the amplifier
Inspect that speaker line.
If the status of the line is correct, you
can adjust the monitoring of the line
and expand the tolerance margin for
detecting the error.
Inspect that speaker line.
If the status of the line is correct, you
can adjust the monitoring of the line
and expand the tolerance margin for
detecting the error.
R +D Department
Modular audio matrix
with IP connection
28

Publicidad

loading