8)
POWER SUPPLY 1
24 VDC primary power input (see figure 10).
9)
POWER SUPPLY 2
24 VDC secondary power input (see figure 11). The power supply inputs have been doubled; therefore, if required by the
safety standards, two independent power supplies may be connected.
10) BUS AUDIO LINK Audio bus expansion connector. it is used for connecting the COMPACT to the COMPACT-E units. To
accomplish this use 34 way flat ribbon cable with 2x17, 2.54mm IDC connectors. When installing the cable be careful to install
the connectors in the same position and side of the flat ribbon cable (see figure 16).
11) FUSE 1. 2.5A primary power fuse.
12) FUSE 2. 2.5A secondary power fuse.
13) Ground connection
4. PLACEMENT OF THE BATTERY
To activate the time schedules, the equipment incorporates an RTC (Real-time clock) whose function is to maintain the current
time. To keep the RTC powered even if the equipment is turned off, we must place a 3V lithium battery type CR2032 supplied with
the equipment.
It is advisable to replace the equipment battery at least every 5 years.
Handling batteries properly:
Warning! Improper use of battery may lead to explosion. Replace the batteries with the same or equivalent type only.
Batteries may endanger life if swallowed. If a battery is swallowed, seek medical assistance immediately.
Before inserting the batteries, check whether the contacts in the device and batteries are clean and, if necessary, clean
them.
Only use new batteries.
Do not use rechargeable batteries
Never try to recharge normal batteries. There is a risk of explosion!
Never expose batteries to heat sources (e.g. radiators) or direct sunlight. There is an increased risk of leakage!
Never short-circuit the batteries.
Never throw batteries into a fire.
Do not disassemble or deform batteries.
If the equipment is not going to be used for long periods, remove the battery.
Remove leaking batteries from the device immediately. If battery acid leaks out it is essential to avoid contact with the
skin, eyes and mucous membranes! If the acid does come into contact with skin, immediately rinse the affected areas with
plenty of clear water and consult a doctor immediately. There is a risk of acid poisoning and acid burns!
Remove exhausted rechargeable battery from the device immediately! There is an increased risk of leakage
Do not throw used batteries into the household waste. The batteries must be deposited in a collection point for used
batteries.