Functioning Modes - Erreka AM600S Manual Del Instalador

Cuadro de maniobra para accionador monofásico
Ocultar thumbs Ver también para AM600S:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

DESCRIPTION OF THE PRODUCT
Slowdown function (DIP 8=ON): function which
reduces the speed of the motor at the end of the
opening and closing operation.
3

FUNCTIONING MODES

Automatic mode (DIP4=ON)
Opening
This begins by enabling the key command (transmitter,
magnetic key, key switch, etc).
• Step-by-step opening (DIP3=ON): if the key
command is enabled during opening, the gate
comes to a halt. The gate closes if operated again.
• Collective opening (DIP3=OFF): during opening,
the control panel does not obey the key commands.
Opening finishes when the opening limit switch opens
(FCA).
Step-by-step mode (DIP4=OFF)
Opening
This begins by enabling the key command (transmitter,
magnetic key, key switch, etc).
• Step-by-step opening (DIP3=ON): if the key
command is enabled during opening, the gate
comes to a halt. The gate closes if operated again.
• Collective opening (DIP3=OFF): during opening,
the control panel does not obey the key commands.
Opening finishes when the opening limit switch opens
(FCA).
20
Installation Guide
STOP pushbutton (emergency stop): this control
panel allows an emergency stop pushbutton to be
installed (STOP). This pushbutton is of NC type
(normally closed). The opening of this contact produces
the immediate halting of the gate. Whilst the contact is
open, DL1 and DL3 flash every 0.5 seconds.
Standby
The gate remains open during the programmed time.
• Automatic mode optional (only if DIP5=ON): if,
during standby, the key command is enabled, the
gate begins to close.
• Non-automatic mode optional (DIP5=OFF): if,
during standby, the key command or the photocell
is enabled, standby time starts again.
Closing
Closing begins automatically after standby. If, during
closing, the key command is enabled, the gate halts and
then inverts operation direction and opens completely.
Closing finishes when the closing limit switch opens
(FCC).
Standby
The gate remains open until a key command is received.
Close
The closing process begins by running the key
command (transmitter, magnetic key, key switch, etc).
If, during closing, the key command is enabled, the gate
halts and then inverts operation direction and opens
completely.
Closing finishes when the closing limit switch opens
(FCC).

Hide quick links:

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Am606s

Tabla de contenido