The unit does not dispense
water.
The boiler is not heating.
Insufficient use of coffee.
Water and steam leak from the
nozzles even when the relative
taps are closed.
Water or steam leaks from
under the knobs of the taps
during opening.
36
Cause
The water mains tap or the purifier taps are
closed.
The water intake union filter is clogged.
Clogged nozzle.
Heating element faulty.
Main switch set to OFF.
The grain size of ground coffee is not correct
(too fine or too coarse).
Spray head and filters partially clogged.
Defective seal or presence of a foreign body
in the seal seat.
Defective tap seals.
15,
TROUBLESHOOTING.
Solution
Open the taps.
Remove and clean.
Check regeneration of the purifier resins.
Clean the nozzle.
Call Technical Service.
Set the main switch to ON.
Check the dispensing time and/or adjust
grinding.
Call Technical Service.
Call Technical Service.
Call Technical Service.