Installation method
Hot water
discharge
This is just the machine installation diagram, the specifics subject to the actual machine!
1. Installation must be carried out by the installation personnel of the company's after-sales department
or its designated installation personnel.
2. The water heater is mounted on the wall.
3. Determine the installation position of the water heater. According to the size shown in Figure 1, drill two
holes on the wall for matching the expansion hook of the attachment with a hammer drill, insert the
expansion hook into the corresponding wall hole, and fix it.
4. Lift the water heater and put the wall rack on the hook. Install the safety valve and other accessories
by referring to "Installing the safety valve" (for installation reference only). Be careful to seal with PTFE
tape to prevent water leakage. Note: Different machines correspond to different wall brackets, installers
can refer to the actual drilling of the bracket installation.
5. To facilitate the installation and disassembly of the water heater, it is recommended to install G1/2
loose joints at appropriate positions of the water heater inlet and outlet pipes. Determine the location of
the water supply, and connect the inlet and outlet water pipes and the inlet water pipes to the water points
respectively. Fill the liner with water, check whether the water is leaking and reconnect if there is water
leakage.
Note: 1. Be sure that the wall bracket is reliably hung on the hook before letting go, in case the water
heater falls, causing personal injury or property damage.
2. The two holes in the hanging frame can ensure the safe installation of the machine.
Cold water pipe
Hot
water
Safety valve
pipe
Sprinkler
head
Cold water intake
:Cold water direction
:Hot water direction
L 1
Figure 1
Volume
(L)
L1(mm)
159
6
50
80
334