Descargar Imprimir esta página

Marvel ML24BCG0 Instrucciones De Instalación página 5

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALLING YOUR BEVERAGE CENTER
Do not remove
ground prong
Figure 3
Figure 4
Figure 5
Front grille screw
All manuals and user guides at all-guides.com
Electrical Connection
A grounded 115 volt, 15 amp dedicated circuit is required.
This product is factory equipped with a power supply
cord that has a three-pronged, grounded plug. It must be
plugged into a mating grounding type receptacle in accor-
dance with the National Electrical Code and applicable lo-
cal codes and ordinances (see Figure 6). If the circuit does
not have a grounding type receptacle, it is the responsibility
and obligation of the customer to provide the proper power
supply. The third ground prong should not, under any cir-
cumstances, be cut or removed.
Ground Fault Circuit Interrupters (GFCI) are prone to nui-
Front grille
sance tripping which will cause the appliance to shut down.
GFCI's are generally not used on circuits with power equip-
ment that must run unattended for long periods of time, un-
less required to meet local building codes and ordinances.
5
WARNING
!
Electrical Shock Hazard
• Do not use an extension cord with this appliance.
They can be hazardous and can degrade product
performance.
• This appliance should not, under any circumstanc-
es, be installed to an un-grounded electrical supply.
• Do not remove the grounding prong from the power
cord. (See Figure 3).
• Do not use an adapter. (See Figure 4).
• Do not splash or spray water from a hose on the
appliance. Doing so may cause an electrical shock,
which may result in severe injury or death.
Figure 6
NOTE

Publicidad

loading