● Do not drive nails into thin boards or near
corners and edges of workpiece. Nails can be
driven through or away from workpiece and
hit someone.
● Never drive nails from both sides of a wall
at the same time. Nails can be driven into
and through the wall and hit a person on the
opposite side.
● Never use Nailer which is defective or
operating abnormally.
● Do not use Nailer as hammer.
● Remove all remaining fasteners and battery
from nailer when:
1) doing maintenance and inspection;
2) checking proper operation of push lever
and trigger;
3) attaching or removing the nose cap;
4) cleaning a jam;
5) it is not in use;
6) leaving work area;
7) moving it to another location; and
8) handing it to another person.
● Remove battery from Nailer when:
1) loading nails;
2) turning the adjuster.
This metabo HPT nailer is equipped with a nailer
operation switching device.
Use FULL SEQUENTIAL ACTUATION MECHANISM or
CONTACT ACTUATION MECHANISM in accordance with
the work to be performed.
Explanation of the various nailing operations
○ FULL SEQUENTIAL ACTUATION MECHANISM:
First, press the push lever against the wood; next,
pull the trigger to drive the nail.
Follow the same sequence to continue driving nails.
After nailing once, nailing will not be possible again
until remove fi nger from the trigger and lift the tool off
the wood surface completely.
○ CONTACT ACTUATION MECHANISM:
1. Pull the trigger.
2. Press the push lever against the wood to drive the
nail.
3. If the trigger is held back, a nail will be driven each
time the push lever is pressed against the wood.
24
The NT1865DMA(S), NT1865DM(S) employs a
preventive mechanism for unloaded operation.
The NT1865DMA(S), NT1865DM(S) enters a state where
the push lever cannot be pushed up. This takes place
when the magazine is not loaded with nails or when the
remaining number of nails becomes less than 6 or 9.
CAUTION
● Use caution not to throw the push lever tip onto
wood when the push lever cannot be pushed up.
METHODS OF OPERATION
This Nailer is equipped with the push lever and does not
operate unless the push lever is depressed.
There are two methods of operation to drive nails with this
Nailer.
They are:
1. Intermittent operation (Trigger fi re):
2. Continuous operation (Push lever fi re):
(1) Intermittent operation (Trigger fi re)
Use
the
FULL
MECHANISM setting.
● For intermittent operation, Set the nailing
operation switch to FULL SEQUENTIAL
ACTUATION MECHANISM (Nailing operation
indicator is light in blue.) (i.e. Set to SINGLE
ACTUATION MECHANISM.)
● To avoid double fi ring or accidental fi ring due
to recoil.
1) Set to FULL SEQUENTIAL ACTUATION
MECHANISM.
2) Pull the trigger rapidly and fi rmly.
1 Set the nailing operation switch to FULL
SEQUENTIAL
(Nailing operation indicator is light in blue.)
2 Position the nail outlet on the workpiece with
fi nger off the trigger.
3 Depress the push lever fi rmly until it is completely
depressed.
4 Pull the trigger to drive a nail.
5 Remove fi nger from the trigger and lift the tool off
the wood surface completely.
To continue nailing in a separate location, move the
nailer along the wood, repeating steps 2 - 5 as
required.