WRM30+ is equipped with a display and two buttons for the user interface. It is organized in two environments: one for
displaying and one to configure. In the first one there is a main screen which summarizes the most important
information of the system; then other main screens show in detail other values. The other environment concerns the
configuration where the operating parameters of the system are set. The various sequences are detailed in the
following tables.
PV module current indicator
Ref.
Description of the funtionality
Pic.5
0.0
Main page.
It displays the battery voltage (V
the day/night status detected by the PV module; The load status icon, if ON, indicates that the load is power supplied.
Finally, there is the low battery alarm. The animation
module, while charging, and towards the load.
0.1
By pressing this button it appears temporarily the current end-charge voltage (i.e. function of detected battery
0.2
temperature), highlighted by "EoC" and then the value for the limitation of recharge voltage in ampere for channel
(temperature derating function or for remote setting).
Pressing and holding for 1 sec. this button it occurs temporarily the system nominal voltage (12V / 24V / 48V),
0.3
evidenced by "SYS" and then the value in Volts. Here you can also see the indication concerning the use of local battery
0.4
voltage (two bars near the battery symbol) or remote (two bars far from the battery symbol).
0.5
1.0
It displays the total charging current of both channels (I
A.B
only the animation of the current in charge. At the beginning of this view there is a temporarily reference to the visualized
channels: in this case "cAb" i.e. the size concerning both channels A+B
1.1
It displays the total charging current
A.0
the main page with only the animation of the current of the PV module. At the beginning of this view there is a
temporarily reference to the visualized channels: in this case "cA" i.e. the size concerning channel A.
1.2
It displays the total charging current from the single module of channel B (I
0.B
main page with only the animation of the current of the PV module. At the beginning of this view there is a temporarily
reference to the visualized channels: in this case "cB" i.e. the size concerning channel B.
2.0
It displays the MPPT research mode. Other indications remain the same of the main page with only the animation of the
A.B
current of the PV module. It shows if the two channels A and B of the PV modules are in parallel or independent. At the
beginning of this view there is a temporarily reference to the visualized channels: in this case "cAb" i.e. the size concerning
both channels A and B.
2.1
It displays the voltage on the module for channel A (V
Charging current indicator
Day/Night status
Charge program
), the charging program currently selected (SEAL, FLOOD or nothing in case of Lithium),
BAT
3
from the single module of channel A (I
WRM30+
User manual
Configuration in progress
Low battery protection
Viewer of internal measures
Pic. 4 Display
1
of the bars indicates presence of current respectively: from PV
I
). Other indications remain the same of the main page with
chA+
chB
). Other indications remain the same of the main page with only
chA
Load status
Load current indicator
Slave-mode indicator
). Other indications remain the same of
chA
). Other indications remain the same of the
chB
EN