10.2.2.2 Entering the target point
A designation that clearly identifies the orientation point must be entered when data is saved.
After the orientation point has been entered, a reading must be taken from the orientation point. When dong so, the
orientation point must be targeted as accurately as possible.
10.2.2.3 Setting a station with a control line
The station is set immediately after the angle measurement for orientation purposes.
NOTE
The station is always saved in internal memory. If the station name already exists in memory, the station must be
renamed. i.e. a new name assigned to it.
After the station has been set, the user can continue with the actual main application previously selected.
10.2.2.4 Shift and rotate axis
Shift axis
The axis starting point can be shifted in order to use a different reference point as the origin of the coordinate system.
If the value entered is positive, the axis is moved forward. If it is negative, the axis is moved back. A positive value
shifts the starting point to the right and a negative value shifts it to the left.
Enter name for the orientation
point.
Return to previous view.
Continue to "Orientation meas-
urement".
Measure angle and distance.
Continue, showing the
(re)calculated station height.
Return to orientation measure-
ment.
Show station data.
Setting the station.
en
37