P0 is the position of the tool after setting up.
If angles and distances to target points are measured, the corresponding building control line distances L and Q are
calculated and saved in memory.
Measuring points with building control lines
Measuring can begin as soon as station setup has been completed.
Cancel and return to options
menu.
Save the horizontal distance, ho-
rizontal angle and vertical angle
values shown in the display.
Measure and save the horizontal
distance, horizontal angle and
vertical angle.
Measure distance.
Toggle the display to distances
between control lines.
Toggle display to angle values.