ELECTRICAL CONNECTIONS
Complete the installation in line with low
voltage regulations and applicable rules.
Use cables with sufficient section, always
earthed.
Check the manufacturer's instructions for all
the elements installed.
Current
regulations
magnetothermic switch to feed the control
board must be fitted. The contact separation at
all poles must provide a total disconnection
under category III overvoltage, in accordance
with
installation
regulations.
characteristics (rated current, voltage, etc.)
must be suitable for the facility and the
elements used.
Case A: operator with encoder (IZS1 - IZS4 - IZS4D) with VIVO-D102(M) board
IZS4D
state
that
a
Its
specific
VIVO-D102(M)
P113F
UNPACKING AND INSTALLATION
O
The operating voltage of the control board
must match the mains voltage (230VAC/ 50-
60Hz for the VIVO-D102, VIVO-D103/ADB30,
VIVO-D203; 125VAC/ 50-60Hz for the VIVO-
D102M, VIVO-D203M).
O
These operators do not require capacitors for
operation.
1 Connect the operator to the control panel as shown
in the diagram.
Cable colours:
G1
Blue (motor)
G2
Red (motor)
–
Mesh (encoder mass: GND, P14)
S
Green (encoder signal: SNG1, P15)
+
Brown (encoder supply: V+, P13)
IZS4D Operator with release: connect the STOP
cable connectors of the operator to the STOP cable
connectors of the control board.
IZS1, IZS4 Operators without release: make an
electrical bridge in the STOP cable connectors of the
control board.
2 Connect the control panel to the electricity supply
(see the control panel manual).
Before carrying out any door movement,
ensure there is no person or object in the radius
of
action
of
the
mechanisms.
3 Check the turning direction of the operator using
the OPEN (OP) and CLOSE (CL) keys on the control
panel.
door
and
the
drive
IZAR chain transmission operator