EXTERNAL CAMERA CONNECTION
Instead of the camera present in the module, an
external camera can be connected to terminal pins
V3, V5.
To enable the external camera, move the jumper as
shown below.
WIRING INSTRUCTIONS WITH CAT5 WIRE
Fit the CAT5 wire in a RJ45 plug with Urmet logo:
•
Insert the wire in the guide respecting the colour coding shown (Standard T568B).
•
Cut the wires which protrude from the guide by approximately 5 mm, insert the guide in the plug and
crimp the plug with a specifi c tool.
Make sure that the grey sheath remains inside the plug.
This type of connection DOES NOT ensure double insulation.
TECHNICAL SPECIFICATIONS
POWER VOLTAGE AND CONSUMPTION ON TERMINALS V+ V-
Power voltage: ...............................................................................................................................44 ÷ 57 Vdc
Current consumption during video call (*) @48 V: ................................................................................200 mA
Current consumption in standby (*) @48 V: ..........................................................................................140 mA
Working temperature range: .................................................................................................. -10 °C ÷ +50 °C
(*) Current consumption of 30 external name holder tags is included.
Relay contact range C, NC, NO:
Maximum switching voltage: ................................................................................................................ 30 V
Maximum switching current: ...............................................................................................................3,5 A
Maximum switching load: ......................................................................................................... 40 VA 25 W
Max. distance from hall button: .............................................25 m with cable cross-section area 0.5 mm
Max. distance from open door sensor: .................................50 m with cable cross-section area 1.5 mm
Max. distance from supplementary power supply: .............100 m with cable cross-section area 1.5 mm
Max. distance from capacitance lock: ................................100 m with cable cross-section area 1.5 mm
DS1039-043A
Wire
No.
1
White-Orange
2
Orange
1
3
White-Green
4
Blue
8
~ 5 mm
1
8
TLC-EXT
Wire colour
1
8
Wire
Wire colour
No.
5
White-Blue
6
Green
7
White-Brown
8
Brown
Plug
2
2
2
2
9