PROBLEM : Problem: Water is leaking from a connection pipe at the rear of the cabin.
SOLUTION :
The stainless steel clamps used to tighten the pipes on the nozzles are not tight enough. Tighten them using pliers and a
screwdriver. If they are defective, contact your dealer.
The water pressure exceeds 4 bars, lower your pressure. The piping is not sized to withstand more than 4 bars of pressure.
PROBLEM : Water is leaking on the floor outside the cabin.
SOLUTION :
If the cabin is not installed perfectly flat or in the event of very weak drain flow, it is possible that water will infiltrate at the level of the screw
holes present on the tray. In this case, pull the cabin to access the back, unscrew the bottom screws and apply a dot of PVC glue in the
hole. Then screw these screws back into the still fresh PVC glue and wait 24 hours for it to dry before putting your cabin back in the water.
The leak may come from the drain. Was the contour of the drain well siliconed during the installation of your cabin, as
recommended in this manual. If this has not been the case, it is necessary to apply a joint of sealing mastic around the edge
of the drain. Also check if the two parts of the drain (inside and outside the cabin) are correctly tightened, as well as the
union nut between the drain and the cabin siphon.
Check the tightness of the 2 hot and cold water inlet hoses. Too much tightening could have loosened the ends of these
hoses. In this case, it is essential to replace them, otherwise you risk water damage.
If necessary, high-pressure rinsing, particularly at the level of the drainage gutters, may cause water to leak outside. The
rinsing of the cabin must therefore be carried out at a reduced flow rate.
PROBLEM : The faucet is leaking.
SOLUTION :
Check that the seals between the wall and the mixer are present and well positioned. Do not hesitate to unscrew the faucet
if it is already fixed to the wall. If you do not see any problem with the seals, check the following points.
The ceramic cartridge located inside the mixer may have shifted. In this case, it is necessary to disassemble this cartridge,
reposition it correctly and reassemble the mixer.
It is possible that the 3 circular seals of the ceramic cartridge located inside the mixer are no longer sufficiently greased. In
this case, disassemble the cartridge, apply a little grease to these seals and reassemble the mixer.
If the problem persists, the cartridge is probably damaged. Contact your dealer.
PROBLEM : The door is poorly adjusted and does not close properly.
SOLUTION :
A first of all, check the tightness of the wheels: you have noticed that the wheels have an off-centre axis. For the closure to
be perfect, it is imperative that the axis of the off-centering is in the same orientation for all the rollers.
It is possible that the facade profiles are not inserted uniformly over the entire length of the glass wall or that these profiles
are not perfectly horizontal or vertical. In this case, push it in all the way and check its horizontality or verticality with a level.
It is possible that the magnetic poles of the two magnetic seals oppose each other. In this case, remove one of the 2 magne-
tic seals and refit it the other way around.
PROBLEM : The chrome elements of the cabin are deteriorated after a few days of use.
SOLUTION :
You have probably used cleaning agents containing acetone, chlorine or ammonia water (bleach) despite the recommenda-
tions on the first page of this manual. The only solution to this problem is to order the stitched items from your dealer.