Descargar Imprimir esta página

SPIDO COMBO PREMIUM 5.5 Manual Del Usuario página 24

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 52
EN
WINTER PERIOD
The filter and pump must be protected
against freezing. The appliance must be
switched off during the winter season.
Remove all water from the filter and pump,
dismantle it and store it in a sheltered,
dry place. Remove the rotor assembly
from the pump, wash it thoroughly, and
store the pump and rotor separately.
Store the unit and accessories in a
dry, temperature- controlled area, 0/40
degrees Celsius. It is recommended to
7. FAULT RESOLUTION
Malfunctions or
breakdowns
The pressure is
The upstream filter is clogged, the pump
too low
does not receive enough water.
Air is in the pump
A leak is present on the suction side of
the pump
The filter is leaking
The seal is damaged
The pump does not
The pump is not connected
work
Residual current circuit breaker (RCD)
has tripped
The pump motor is defective
keep the filter open during storage. You
can reuse the original packaging to store
the product and accessories.
WARNING!
Limescale deposits and natural wear of
the components may cause an increase
in the noise of the pump, but do not
affect the proper functioning of the pump
in any way. In this case, we recommend
replacing the entire rotor.
Cause
Clean the upstream filter, check the
suction line and the water level
Retighten the hose connections and
tighten the screws
Loosen the transparent cover of the filter
cartridge (do not unscrew completely)
to release the trapped air. Screw the
cover back on tightly when all the air has
escaped.
Check the seal
and replace it if necessary
Check the plug and the power cord
Reset the RCD residual current circuit
breaker. If it trips again immediately, the
pump or the controls are defective
Replace the entire pump
Solution

Publicidad

loading

Productos relacionados para SPIDO COMBO PREMIUM 5.5

Este manual también es adecuado para:

Combo premium 7.0Combo premium 9.5002965002966002967