EN
•
Stop immediately if the equipment leaks oil. Oil escaping under pressure can penetrate the skin and
cause serious injury. Go immediately to a hospital with a person who is injected with oil for medical
help. Give a specification of the oil to the medical staff.
•
Always adhere to the safety regulations that apply to other equipment that is used in the operation.
2.7
Safety regulations with respect to maintenance
•
Wear personal means of protection when performing maintenance tasks.
•
Never work in a way that could jeopardize safety.
•
Make sure that the equipment cannot roll away or tip over. The control and drive must be switched
off and safeguarded against unexpected activation.
•
Make sure that moving parts do not move unexpectedly.
•
Used or leaked fluids, and any other products consumed during the activities, must be collected and
disposed of in a environmentally responsible way.
3
Description
3.1
Equipment
The pump is an independent, reliable power source to which hydraulic tools can be connected.
The electric motor or four-stroke petrol engine runs a two-stage radial piston pump that can build up a
maximum pressure of 500 bar.
Each pump has 2 safety valves to limit the maximum pressure. The settings of one of the valves can be
changed to a lower maximum pressure by an Holmatro certified technician. The other valve is sealed
and can not be changed. If in doubt, consult the Holmatro dealer.
The IPU-M version is suitable for hydraulic tools which have their own control system.
3.1.1
Type designation
The model code of the "2035" series differs from the standard model code: see example 2.
Example 1: IPU-M 06 W 6 SD
/i
Digit
Example
1-5
IPU-M
6-7
06
8
W
9
6
10
S
11
D
30
Description
Industrial Pump for mobile application
Pump delivery capacity:
06 = 0.6 l/min
12 = 1.2 l/min
32 = 3.2 l/min
Type of pump:
W = double stage
S = single stage
Volume of hydraulic oil tank:
6 = 6 l
Material of the tank:
S = steel
Type of drive:
D = electric motor, 230 V, 50 Hz, single phase
E = electric motor, 400 V, 50 Hz, three phase
M/K = electric motor, 200/220 V, 50/60 Hz, three phase
Q = electric motor, 110 V, 50 Hz, single phase
916.219.173_005
1
IPU-M