Indoor use
Impermeability: protection index IP 40 (according to EN
60529, ed. 92)
4.5 Compliance with norms
Electrical safety
(as per EN 61010-1 ed. 95 and 61010-2-032, ed. 93)
-
Dual insulation:
-
Installation category: III
-
Pollution level: 2
-
Rated voltage: 600 V (RMS or DC)
or -
Installation category : IV
-
Rated voltage : 300V (RMS or DC)
Electric shocks (test as per IEC 1000-4-5)
- 6 kV in RCD mode on the voltmeter function, aptitude
criterion B
- 2 kV induced on the current measurement cable , aptitude
criterion B
Electromagnetic compatibility
(as per EN 61326-1 ed. 97 + A1)
Emission: class B
Immunity:
- Electrostatic discharges:
4 kV on contact, aptitude criterion B
8 kV in the air, aptitude criterion B
- Radiated field: 10 V/m, aptitude criterion B
- Fast Transients: 1 kV, aptitude criterion B
- Conduit interference: 3 V/m, aptitude criterion A
Mechanical resistance
- Free fall 1 m (test as per IEC 68-2-32)
- Impacts: 0.5 J (test as per IEC 68-2-27)
- Vibrations: 0.75 mm (test as per IEC 68-2-6)
Auto power OFF (per UL94)
- Housing: V0
- Jaws: V0
- Display window: V2
42