USING
THE CLEANER
CONTROL PANEL
A - On/off switch
B - Temperature regulator
C - Detergent control tap (if
available).
D -
Pressure gauge.
STARTING THE CLEANER
1) Turn on the water supply tap (fig. 5A).
2) Connect the water cleaner to the mains electricity supply via
the omnipolar switch or by plugging the plug into the socket.
3) Start the cleaner by turning the selector switch to pos. 1
(fig. 5A).
!
Warning
The high pressure water jet generates a reaction force in the
lance. Keep a firm grip on the lance handle.
4) Press the trigger on the gun and begin washing.
5) To use the cleaner with hot water, turn the temperature regu-
lator (fig. 7B) to the recommended washing values.
For some models turn the ignition switch (fig. 7A) on to the
hot water position before effecting the operations described
in this point.
!
Warning
In water cleaners with the "Total Stop" system, the motor starts
and stops when the lever on the lance handle is actioned or
released.
!
Danger
Do not block the handle lever in the delivery position.
IMPORTANT!
To eliminate any impurities
or air bubbles from the wa-
ter circuit we advise starting
the cleaner for the first time
without the lance and letting
the water run out for a few
seconds.
Impurities could block the
nozzle and cause malfunc-
tion (Fig. 8).
English
USING THE ACCESSORIES.
The high pressure washer has a nozzle with a flat angle jet for
cleaning large surfaces.
!
Warning
Aim the jet from a certain distance to avoid damage caused by
the high pressure.
ROTARY HEAD (optional accessory)
The high pressure washer can be fitted with a head with rotary
nozzle to clean the most stubborn dirt.
!
Danger:
FIG. 7
Aim the jet from a certain distance to avoid damage caused by
the high pressure.
Do not aim the jet at people, animals or electrical sockets.
STOPPING THE CLEANER
1) Switch off the burner by turning the pressure regulator to
pos. "0" (fig. 7B).
2) Let the cleaner run with cold water only for at least 30 seconds
to cool down the boiler.
3) Stop the cleaner by turning the selector switch to pos. "0"
(fig. 7A).
4) Discharge the pressure from the H.P. hose by pressing the
trigger on the gun.
5)
Disconnect the water cleaner from the mains electricity
supply via the omnipolar switch or by unplugging the plug from
the socket.
6) Turn off the water supply tap (fig. 5A).
!
Warning
- If the water cleaner is left,
even temporarily, turn it off by
using the omnipolar switch or
by unplugging the plug from
the socket.
- Water cleaners with the
"Total Stop" device should
be considered as off when
the omnipolar switch is in
the "O" position or the plug
is unplugged from the sock-
et.
- When the water cleaner is not
used, close the safety device
on the handle.(fig. 9)
- Dry use of the water cleaner
causes serious damage to
pump gaskets.
FIG. 8