Push the "Lower into catches" button u (10) on
the operating element.
• Precise alignment of the columns (1) using a
bubble level.
• Tighten anchors with a torque wrench.
• Assembling the drive-in ramps and the rollover
safety.
• Set the sliding guide on the cross-beam with
a play of approx. 4-5 mm between the sliding
guide and lift column.
• Set equal rail height on all four lift columns by
adjusting the nuts with which the load cables are
fastened in the head plates.
i To achieve the required measurement accu-
racy for all well-known vehicle manufacturers it
is important to set up and level the lift platform
as precisely as possible. For this, the following
work steps must be done:
• Lift the platform to eye level and lower into the
catches.
• Position each of the measurement channels
from the outside to the cross-beams and check
and ensure each drive track has the same le-
vel using the levelling device.
• Precisely align the drive-in rails by adjusting the
fastening screws of the safety ratchets on the
head plate.
4.10 Adjusting the drive-in rails
The standard dimension between both drive-in
rails is 850 mm. However there is the option of ad-
justing the right drive-in rail in the driving direction
by 3 x 50 mm (a total of 150 mm).
For this, the lift must be set down into the catches
(14) so that there are no tensional forces on the
cables which could make adjusting the drive-in
rails more difficult.
• Move the vehicle out of the lift
• Set down the lift into the catches.
• Remove the ramps and safety override on the
adjustable rails.
• Remove both covers (front side of the cross-be-
ams).
• Loosen and remove fastening screws on the
drive-in rails.
20110006 OPI
25.09.2015
COMBI LIFT 4.40 S-S A-S PLUS-S PLUS AMS - HYMAX II 4000 S-S A-S PLUS-S PLUS AMS
• Slide the drive-in rails to the desired size.
• Replace and tighten the fastening screws on the
drive-in rails.
• Replace and fasten both covers.
• Replace the ramp and safety override.
• Raise the lift out of the catches (push the "LIFT"
button o (8)).
• The lift returns to normal working function.
5
Operating manual
When handling the system, it must ab-
solutely comply with safety regulations.
Carefully read the safety regulations in
Section 3 before first operation!
To prevent operation by unauthorized
people, secure the main switch (7).
5.1
Operating element
Main operating elements
8
10
9
Main operating elements
7
Main switch
o
8
LIFT
u
9
LOWER
12
Unit cover
7
11
12
005
7
Light ON / OFF
10
Lower into catches
11
Bridging button
51