Nussbaum ATT COMBI LIFT CL 4.40 S Instrucciones De Servicio página 54

Libro de inspeccion
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

• Lubricate all lubrication nipples with a multi-pur-
pose grease.
• Check set down catches for ease of latching and
clean and lightly lubricate friction surfaces.
• condition of the load cable: if wire breaks can
be seen on a a wire cable, the entire cable set
must be exchanged.
• check all available safety devices for function.
e.g. catches, switch, CE stop, warning signal,
main switch, return and rollover safeties, etc.
• check hydraulic oil for wear. The oil is used if it
has a milky colour or if the hydraulic oil smells un-
pleasant.
• All weld seams must have a visual inspection.
Stop the system and contact the manufacturer if
there are cracks or breaks in weld seams.
• check galvanized surfaces and touch up as
needed. White rust is fostered by permanent hu-
midity, poor ventilation.
Rust is brought out by mechanical damage, wear,
aggressive deposits (de-icing salt, leaking opera-
ting fluids) cleaning that is not done or incomplete.
The affected areas can be treated by using a
sanding cloth (A 280 grit). If required, the parts
are to be treated with a suitable, resistant mate-
rial (paint etc).
• check the filling level of the hydraulic oil.
• check the protective hose and hydraulic hoses:
Check the condition of the protective hose
around the hydraulic lines. These should be ex-
changed if there is damage. When doing this,
hydraulic lines are absolutely to be checked for
possible crushing points. Lines which have been
crushed must be exchanged. Otherwise pressu-
rized hoses must be exchange as required, ho-
wever at latest after 6 years.
Hose lines are to be replaced:
• for damage to the outer coating up to the in-
sert (chafe marks, cuts, cracks)
• for brittleness of the outer coating (crack for-
mation), deformation of the natural shape in
the depressurized and in pressurized states.
54
COMBI LIFT 4.40 S-S A-S PLUS-S PLUS AMS - HYMAX II 4000 S-S A-S PLUS-S PLUS AMS
• if leaking
• for damage or deformation of the mounting
fixture
• if the mounting fixture has meandered
• if the lifetime has been exceeded
Repair of the hose line using the implemented
hose / mounting fixture is not permitted!
Extending the replacement intervals given in the
guideline is possible if the inspection for safe-work
condition is done in adjusted, shortened time fra-
mes, if required and by competent personnel.
If ther is an extension of the replacement inter-
val, no situation may occur which could result in
injury of employees or other personnel.
• The condition and function of the wheel jacks
are to be checked.
• check the torque of the fastening anchor. See
the data sheet for the relevant anchor manufac-
turer.
• check the torque of the fastening screws. Also
see the assembly protocol.
Torque (Nm) for shaft screws
Fastening class 8.8
0.08*
M8
17.9
M10
36
M12
61
M16
147
M20
297
M24
512
Fastening class 10.9
0.08*
M8
26.2
M10
53
M12
90
M16
216
M20
423
M24
730
*
Lubricated slide friction number 0.8 MoS2
**
Lightly oiled slide friction number 0.12
*** Ensured slide friction number 0.14 screw
with micro-encapsulated plastic
0.12**
0.14***
23.1
25.3
46
51
80
87
194
214
391
430
675
743
0.12**
0.14***
34
37.2
68
75
117
128
285
314
557
615
960
1060
25.09.2015