Fig. 8: Overview of AES series 500 adapter module
1 Adapter module
3 Hexagonal socket-head screw
M4 x 40 mm
Fig. 9: AES series 500 adapter cable
1 Adapter module
1. Mount the bus coupler with 3 hexagonal socket-head screws M4 x 40 mm and
the washers on the left side of the adapter module.
Tightening torque: 1.6 Nm ± 0.2 Nm
2. Connect the adapter module to the valve system using the supplied connec-
tion cable: Attach the 2-row plug connector onto the board of the adapter
module. The cable exit points upwards.
3. Join the bus coupler and the adapter module with the valve system on a flat
surface.
4. Screw the bus coupler and adapter module with 4 hexagonal socket-head
screws M4 x 16 mm to the corresponding valve system (e.g. series 501).
Tightening torque: 1.6 Nm ± 0.2 Nm
7 Commissioning
Follow the steps below to carry out commissioning.
7.1 Basic requirements
Personnel qualifications
Commissioning only by qualified personnel. See
Product-specific requirements
• Ensure that all plug connector seals and plugs are leaktight (prevention of in-
jury, material protection).
7.2 Notes on safety
To eliminate risks during commissioning, observe the notes on safety. See
g 2. Safety.
7.3 Preparation
General requirements
• Ensure that the product is not put into operation if defects have been de-
tected (accident prevention, material protection).
AVENTICS™ AES | R412018150-BAL-001-AC | English
2
M = 1.6 Nm ± 0.2 Nm
D
4
3
M = 1.6 Nm ± 0.2 Nm
D
2 Hexagonal socket-head screws
M4 x 16 mm
4 Washers
1
g 2.5 Personnel
qualifications.
• Observe the system descriptions for your valve system components. See
g 1.2 Additional
documentation.
• Observe PLC configuration files. See
Product view in the PLC configuration program
In the PLC configuration program, the product is displayed as "Valve
driver (32DO-BDESIGN)".
7.4 Step-by-step commissioning
If you have carried out and completed all preparation work, you can commission
the system.
8 Data and parameters
The data and parameters in the following tables apply to the end product in
which this product is installed.
For further information, refer to the bus coupler instructions. See
tional
documentation.
8.1 Process data
Byte Z corresponds to the start address set in the control.
Table 2: Byte Z
Bit
0
1
2
3
4
5
6
7
Table 3: Byte Z+1
Bit
0
1
2
3
4
5
6
7
Table 4: Byte Z+2
Bit
0
1
2
3
4
5
6
7
Table 5: Byte Z+3
Bit
0
1
2
3
4
5
6
7
g 1.2 Additional
documentation.
g 1.2 Addi-
Valve
Coil
1
14
12
2
14
12
3
14
12
4
14
12
Valve
Coil
5
14
12
6
14
12
7
14
12
8
14
12
Valve
Coil
9
14
12
10
14
12
11
14
12
12
14
12
Valve
Coil
13
14
12
14
14
12
15
14
12
16
14
12
20