1.6 ELECTRICAL CONNECTION
When the appliance is delivered it is set to work at the voltage given
on the rating plate affixed on the right side of the appliance.
The effectiveness of the equipotential system of which the appliance is
part of, must conform to current standards.
Connect using the screw you find in the back side of the oven, marked
with the word EQUIPOTENTIAL.
The Manufacturer declines all and every responsibility if this important
accident prevention norm is not complied with. If the feeding cable is
damaged, it must be replaced by the technical service or in any case
by similar qualified personnel, in order to avoid any risk.
1.7 TECHNICAL DATA FOR ELECTRICAL CONNECTION
Model
4 x 1/1 GN- 60x40
Electric
5 x 1/1 GN- 60x40
Electric
6 x 1/1 GN- 60x40
Electric
7 x 1/1 GN- 60x40
Electric
10 x 1/1 GN- 60x40
Electric
12 x 1/1 GN- 60x40
Electric
4 x 1/1 GN- 60x40
Gas
5 x 1/1 GN- 60x40
Gas
6 x 1/1 GN- 60x40
Gas
7 x 1/1 GN- 60x40
Gas
10 x 1/1 GN- 60x40
Gas
12 x 1/1 GN- 60x40
Gas
All manuals and user guides at all-guides.com
Power loading
no. and motor
and voltage
6.5 kW
380 - 415 V 3N~
2 x 240 W
50 Hz Analog
50/60 Hz Touch
11.6 kW
380 - 415 V 3N~
2 x 240 W
50 Hz Analog
50/60 Hz Touch
17.3 kW
380 - 415 V 3N~
3 x 240 W
50 Hz Analog
50/60 Hz Touch
0.3 kW
220 - 240 V 1N~
1 x 240 W
50 Hz Analog
50 Hz Touch
0.3 kW
220 - 240 V 1N~
1 x 240 W
50 Hz Analog
50 Hz Touch
0.6 kW
220 - 240 V 1N~
2 x 240 W
50 Hz Analog
50 Hz Touch
Heating
power
power
6.0 kW
11.0 kW
16.5 kW
--
--
--
12
Absorbed
Feed cable
current
section
10.0 A
5 x 2.5 mm
18.0 A
5 x 4.0 mm
26.0 A
5 x 6.0 mm
1.2 A
3 x 1.5 mm
1.2 A
3 x 1.5 mm
2.4 A
3 x 1.5 mm
2
2
2
2
2
2

Publicidad