Recommended installation space
For maintenance operations to take place, there must be:
- a clear space of at least 50 cm in front of the plastic cover to allow access to the lateral flange,
- direct access to the safety assembly,
- particular case of installation in a bathroom (NF C15 100).
Advice :
To prevent overconsumption of energy, it is recommended
that the heater be positioned as closely as possible to the
hot water usage points. (a distance of less than 8 metres is
recommended).
Water connection and preliminary operations
- Verify that the useful thermal power from the generator exceeds the power that the tank can absorb by more than 15%.
- Verify that the volumes and the pre-charge pressure of the secondary circuit expansion reservoir are suitable for the system.
- If the water in the circuit is excessively hard (TH > 25°F), install (upstream of the tank), a correctly adjusted water softener.
- If impurities are found in the water in the circuit, install a suitable filter, making sure that the circulators have sufficient flow and a sufficient
extractor and that they rotate regularly.
- Verify that the thermostat sensor is correctly positioned.
- Verify that the thermostat controls are functioning correctly, if using an optional electrics kit.
- Install a safety assembly that meets current national and EU standards, and which is suitable for the maximum working pressure
indicated on the product identification label.
Technical Installation Instructions and User Guide
Definition :
Space envelope (A): The space envelope is the space outside the bathtub
or the shower basin, and is limited on one side by the vertical cylindrical
surface around the bathtub or shower basin, and on the other side by the
horizontal plane 2.25 m from the base of the bathtub or shower tray.
Protection space (B): The protection space is the accessibility area for a
person inside the bathtub or the shower basin, which lies outside the spa-
ce envelope. It is limited by the vertical cylindrical surface 0.60 m from the
base of the bathtub or the shower basin and limited by a horizontal plane
located 2.25 m above the base of the bathtub or shower basin.
This standard is applicable in France, and of course the installer must re-
main aware of any changes to this standard. For installation in other coun-
tries, please refer to the applicable local regulations.