Troubleshooting
Error
Water pump
not working
Massage jets
do not start
Bathtub is not
level
Water overflow
Cleaning
1.
Use a soft cloth for cleaning purposes, avoiding the use of strong detergents that contain
acetone or ammonia. It is strictly prohibited to disinfect using formic acid or formaldehyde.
2.
If there is a scratch on the surface, utilise 2000-grit wet sandpaper to gently polish it.
Afterwards, proceed to polish it further using toothpaste and a soft cloth.
Possible Reasons
The power plug is not properly
connected; the leak protection is not
connected
The water pump impeller is blocked by
something small
The water pump is turned off
The power plug has not been inserted
correctly
Broken water pump
Voltage issue
On/Off button is not on or not
functioning
Water circulation is blocked
Adjustable feet are not set correctly
Overflow drain is defective
Nuts are loose
Connecting parts are not correctly
attached
Try This
Plug in the power plug and connect
the leak protector
Clean the water pump impeller
Turn on the water pump.
Plug in the power supply correctly
Repair or replace the water pump
Check the voltage
Check the switch or replace it
Clean the water pipes
Adjust the feet
Replace the overflow drain
Tighten the nuts
Inspect the adhesive of the connecting
parts
16