HOW TO OPERATE THE BURNER
4, Adjusting the flame
Install and position the flame of the circular furnace head IEB-R46.
Note: When adjusting the flame, it must be done before ignition or after extinguishing the burner and
cooling. Do not remove the metal sheet while the burner is burning!
The IEB-R46 burner has three levels of flame.
Minimum: Close 6 metal plates.
Medium: Open 3 metal plates.
Maximum: Open 6 metal plates.
Minimum Fire
Medium Fire
Maxmum Fire
5, Re-igniting the burner
NOTE: ASSUME BURNER IS LIT, EVEN IF YOU DON'T SEE FLAME.FOLLOW PROCEDURE TO
EXTINGUISH FLAME AND ALLOW UNIT TO COOL BEFORE ATTEMPTING TO REFUEL. NEVER
REFUEL WITH BURNER LIT OR WHILE UNIT IS HOT.
Wait 30 minutes before re-igniting the Burner. The Burner should be at room temperature. Please be
aware that if this time is not respected the ignition could be pressurized and therefore stronger.
A pressurized ignition can cause serious burns if you are close to the Burner.
9 / 52