38
9.6
BOTTLE UNLOADING KIT
(Fig. 14): If the spiral springs in the tray have a five
product capacity, insert the bar in hole "A" ; whereas
if the spiral springs have a four product capacity
then insert the bar in hole "B"; if the tray have
selections by product support, insert the bar in hole
"C".
E
N
G
L
I
S
H
FAS INTERNATIONAL S.p.A. Via Lago di Vico, 60 SCHIO (VI) – tel. +39 0445 502011 – fax +39 0445 502010 - e-mail: info@fas.it
If the product support elements (FIG. 15)
have been mounted in the lower tray, it is
advisable to control that they are fixed
correctly directed towards the inside, so
that they do not impede the spring and
the delivery door from rotating.
Periodically check that the condensation
waste outlet (FIG. 16), located on the
cabinet base, is not obstructed by any
dirt or ice build up.
If necessary clean it thoroughly by
removing dirt or ice.
If ice build up occurs often check the
calibration of the rear digital thermostat.
10 WARNING
BABY FAS – Issue 04
Fig. 14
FIG. 15
FIG. 16