Descargar Imprimir esta página

ELEMENTI Boulder OFG110LP Manual Del Usuario página 6

Publicidad

Idiomas disponibles

Idiomas disponibles

PROPANE (LP) DANGERS AND WARNINGS
• The LP gas tank must have a tank collar to protect the tank valve.
• LP gas cylinder must contain a shut-o valve as specified in the Standard for Compressed Gas
Cylinder Valve Outlet and Inlet Connection, ANSI/CGA-V-1-1977, CSA B96.
• The LP gas tank should not be dropped or handled roughly.
• Tanks must be stored outdoors out of the reach of children. Do NOT store in a building, garage,
or any other enclosed area.
• Never store your LP gas tank where temperatures can reachover 125°F.
• Do not store the LP gas cylinder in direct sunlight or near a source of heat or combustion.
• Never keep a filled LP gas tank in a hot car or car trunk. Heat will cause the gas pressure
to increase, which may open the relief valve and allow gas toescape.
• Place dust cap on valve outlet whenever the LP gas tank is not in use. Only install the type of
dust cap on the LP gas tank valve outlet that is provided with the LP gas tank valve. Other types
of caps or plugs may result in leakage of propane.
a. Do not store a spare LP gas cylinder under or near this appliance.
b. Never fill the LP gas cylinder beyond 80% full.
c. If the information in (a) and (b) is not followed exactly, a fire causing death or serious
injury may occur.
• LP gas cylinders should be filled only by a certified LP gas dealer.
• The pressure regulator is set for 11 inches of water column (pressure).
• The maximum inlet gas pressure for this outdoor fire table is 14 inches of water column
pressure.
• Never attempt to attach this appliance to the self-contained LP gas system of a camper trailer,
motor home or house.
• Always use the pressure regulator and hose assembly provided with the appliance to connect to
a LP gas cylinder. Never connect to an unregulated LP gas supply. Please contact Elementi at
800-678-7294 for technical support.
• Hand turn the manual gas control valve. Never use tools. If the valve will not turn by hand, do
not try to repair it. Call a Certified Gas Technician. The use of force or any self attempted repair
may result in a fire or explosion.
Connecting your gas cylinder
Before connection, be sure that there is no debris caught in the head of the gas cylinder, head of
the regulator valve or in the head of the burner and burner ports. Connect regulator valve and
hand-tighten firmly. Disconnect the propane cylinder from the regulator valve when the fire table
is not in use. DO NOT obstruct the flow of combustion air and ventilation air to the burner.
6 / 20

Publicidad

loading