50860 Series High Pressure Centrifugal Pump
CYCLONE PUMP
Stainless Steel DC Motor / Pump Unit
A range of Stainless Steel General Purpose Centrifugal pumps
designed specifically for the marine and industrial markets. Typical
applications would be for circulation applications such as hot
water systems.
FEATURES & BENEFITS
• Heavy duty robust design
• Stainless steel construction
• Long life DC motor
• Silent running
• Anti-clog impeller design
• Long life mechanical seal
• Single tool servicing
SPECIFICATION
• Recommended Duty — Max. 30 minutes on, Min. 30 minutes off
• Motor life 2,500 hours
• 6.5ft (2m) suction lift when wetted
• Fluid temperature 39°F (4°C) min 203°F (95°C) max
RELEVANT STANDARDS
• ISO 8846 MARINE and USCG Regulations for Ignition
Protection
• ISO 8849 MARINE Bilge Pump Standard
WARNING: Continuous running of
pump will cause motor casing to get hot.
DO NOT touch — burns may occur.
WARNING: Do not pump petrol or fluids
with a flash point below 100°F (37.8°C).
Explosion and death may occur.
PERFORMANCE CURVE
50860 - Series Cyclone Performance
Typical performance based on pumps running
at 12.8V and 25.6V DC
20.3 (1.4)
17.4 (1.2)
14.7 (1.0)
Total
11.6 (0.8)
head
psi (bar)
8.7 (0.6)
5.8 (0.4)
2.9 (0.2)
0
0
5.3 (20)
10.6 (40)
15.9 (60)
21.1 (80)
Flow
gpm (lpm)
PART NUMBERS
Model
50860-0012
50860-0112
50860-2012
50860-0024
50860-2024
INSTALLATION INSTRUCTIONS
• The Cyclone pump can be mounted on any flat surface.
• The pump must be installed below the lowest fluid level to
maintain flooded suction.
• Fit pump in a dry, well ventilated position. Use rubber grom-
mets provided to minimize vibration.
• If mounted vertically, ensure the motor is above the pump
head.
• Use 3/4" pipe fittings with PTFE pipe joint tape or compound.
• Plastic fittings should not be used if pump is installed below
the waterline.
WARNING: All marine pumps discharging
overboard must be installed with the overboard
discharge well above both static and heeled
waterlines. Flooding and death may occur.
OPERATION
• Pump may be run dry for short periods of time.
• Pump may be run against a closed discharge.
MAINTENANCE
• Check all electrical connections periodically.
• Check seal area for signs of leaking.
26.4 (100)
2
Voltage
Ports
12Vdc
NPTF
12Vdc
NPTF
12Vdc
BSPF
24Vdc
NPTF
24Vdc
BSPF
Discharge
Right
Left
Right
Right
Right