Descargar Imprimir esta página

Xylem JABSCO Cyclone 50860 Serie Manual De Instrucciones página 3

Bomba centrífuga de alta presión

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 18
EXPLODED VIEW
Vue éclatée / Explosionszeichnung / Vista esplosa
Explosietekening / Sprängvy / Vista explotada
1
2
SPARE PARTS LIST
A
Pump Head Kit (NPT)
B
Seal Kit
KEY
DESCRIPTION
1
End Cover
2
Screws
3
O-Ring
4
Locking Nut
5
Impeller
6
Seal
7
Body
8
Slinger
9
Motor
WARNING: Motor may get hot after
prolonged use, do not touch.
Burns may occur.
WARNING: If the fuse fails repeatedly,
do not fit a heavier fuse or bridge the
terminals. Fire and death may occur.
WIRE SIZE TABLE
Model
Voltage
Number
50860-XX12
50860-XX24
* Wire length from battery to pump and back to battery, maximum voltage drop 10%
7
5
3
4
50864-0000
50875-0000
KIT KEY QTY
A
1
5
1
1
1
1
Maximum
Current
12V
21A
24V
10A
9
6
8
WIRING INSTRUCTIONS
• All electrical wiring should be connected and installed by a
competent electrician. A qualified person must ensure that the
installation conforms to the regulations in place.
• Ensure connections are of the correct polarity red/ orange
(+ve) black negative (-ve). Note; if wired in reverse the pump
B
will still run but give poor performance.
• Always use the correctly rated fuse or circuit breaker. If a circuit
breaker is used it should be of the "conditionally surge current
5
proof" type.
1
• Check that the supply voltage is compatible with the voltage
specified on the label. A discharged battery will result in
1
reduced pump performance.
1
Overload
Protected
Distribution
Panel
1
Battery
Fuse
Size
25A
15A
3
Orange
Black
Inlet port
Wiring Size
AWG
mm²
14
6.0
10
15.0
16
4.0
14
6.0
Wiring Diagram
Fuse
Outlet
port
Max. Length*
15 ft (4.5m)
30 ft (9.0m)
15 ft (4.5m)
30 ft (9.0m)

Publicidad

loading