Descargar Imprimir esta página

geberit 115907KJ6 Manual página 38

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 108
EN
Menu item
[Detection range]
[Save as
presetting]
[Restart end
device]
[Factory settings]
38
Description
As soon as an object is located in
the detection range, the red LED
in the sensor window lights up. No
flush is actuated. The function
switches off automatically after 10
minutes.
• User recognition: The sensor for
the user recognition detection
range is activated. LED lights up
and app turns green = User has
been detected.
• Manual flush actuation: The
sensor for the manual flush
detection range is activated.
LED lights up and app turns
green = Hand has been
detected.
• Proximity detection: The sensor
for the proximity detection range
is activated. LED lights up and
app turns green = User is
moving in the detection range.
The [detection range] for user
recognition can be adjusted in 3
steps.
The current settings are saved in
the app, which means they can be
transferred to other devices of the
same type.
The WC flush control is restarted.
All functions are reset to factory
settings.
Application
• To check the user
recognition
• To optimise the
detection range for user
recognition
• To commission several
devices with the same
settings
• To remedy
malfunctions
• To remedy
malfunctions
Value
Factory
setting
[User recog-
nition],
[manual
flush
actuation],
[proximity
detection]
Short
Medium
Medium
Long
4 / 4