DOUBLEINSULATION
Doubleinsulation is a concept i n safetyin electric power
tools, which eliminatesthe need for the usual three-
wiregrounded powercord.All exposedmetalpartsare
isolatedfromthe internalmetalmotorcomponents w ith
protecting insulation. Double insulated toolsdo not need
tobegrounded.
A
WARNING:The
double insulated system is intended
to protect the user from shock resulting from a break
in the tool's internal insulation. Observe all normal
safety precautions to avoid electrical shock.
NOTE: Servicing of a product with double insulation requires
extreme care and knowledge of the system and should be
performed only by a qualified service technician. For service,
we suggest you return the product to your nearest authorized
service center for repair. Always use original factory replace -
merit parts when servicing.
ELECTRICAL
CONNECTION
This product has a precision-bulk electric motor. It should
be connected to a power supply that is 120 volts, AC only
(normal household current), 60 Hz. Do not operate this
product on direct current (DC). A substantial voltage drop
will cause a loss of power and the motor will overheat. If
the product does not operate when plugged into an outlet,
double-check the power supply.
EXTENSION
CORDS
See Figure 1, page i.
When using a power tool at a considerable distance from
a power source, be sure to use an extension cord that has
the capacity to handle the current the product will draw. An
undersized cord will cause a drop in line voltage, resulting in
overheating and loss of power. Use the chart to determine
the minimum wire size required in an extension cord. Only
round jacketed cords listed by Underwriter's Laboratories
(UL) should be used.
When working outdoors with a product, use an extension
cord that is designed for outside use. This type of cord is
designated with "WA" on the cord's jacket.
Before using any extension cord, inspect it for loose or ex -
posed wires and cut or worn insulation.
A proper extension cord is available at an authorized service
center.
It is possible to tie the extension cord and power cord in a
knot to prevent them from becoming disconnected during
use. Make the knot as shown in figure 1, then connect the
plug end of the power cord into the receptacle end of the
extension cord. This method can also be used to tie two
extension cords together.
**Ampere
rating (on product data plate)
0-2.0
2.1-3.4
3.5-5.0
5.1-7.0
7.1-12.0
12.1-15.0
Cord Length
Wire Size (A.W.G.)
25'
16
16
16
16
14
14
50'
16
16
16
14
14
12
100'
16
16
14
12
10
--
**Used on 12 gauge - 20 amp circuit.
NOTE: AWG = American
Wire Gauge
WARNING:
Keep the extension cord clear of the
working area. Position the cord so that it will not get
caught on lumber, tools, or other obstructions while
you are working with a power tool. Failure to do so
can result in serious personal injury.
WARNING:
Check extension cords before each
use. If damaged replace immediately. Never use the
product with a damaged cord since touching the
damaged area could cause electrical shock resulting
in serious injury.
8 - English