6.4 BLADE OPENING
ADJUSTMENT (FIG. 6)
To adjust the opening of the movable blade:
1. press the ON / OFF switch to activate the
machine (Fig. 1 L)
2. press the ON / OFF switch to choose the
operating mode:
mode "1" - a green light, to cut branches
with a diameter up to 15 mm (fig. 6 I);
mode "2" - two green lights, to cut branches
with a diameter up to 25 mm (fig.6 II);
mode "3" - three green lights, to cut branches
with a diameter up to 30 mm (fig. 6 III)
6.5 STOP
To stop the machine:
1. Release the trigger
2. Press and hold the ON / OFF switch for 2 sec
3. Wait for the beep
4. Remove the battery from its seat
5. Put on the protective cover
Do not touch the blade while it is moving.
Always stop the machine:
– when moving between work areas.
 Do not keep your finger on trigger when 
moving the machine to avoid accidentally
enabling the machine.
7. ROUTINE MAINTENANCE
7.1 GENERAL INFORMATION
The safety regulations to follow are
described in chap. 2. Strictly comply with
these instructions to avoid serious risks or
dangers.
Before
conducting
cleaning
or
interventions on the machine:
• Stop the machine;
• Remove the battery from its housing;
Frequent checking of the tool will make it safe and
reliable:
• Do not spray water on the tool and do not
immerse it, it can cause short circuits inside the
tool.
• Keep the handle, any motor ventilation devices
clean, use a cloth to clean the tool. Do not use
detergents to clean the tool to avoid damaging the
surfaces.
any
inspections,
maintenance/adjustment
• Clean the blade after each use, protect it with
protective oil or spray (Fig.7)
• Only when necessary, tighten the fixing
mechanism (Fig.1 C) by using the supplied socket
wrench (Fig.1 K).
7.2 BATTERY
7.2.1 Battery power reserve
Battery autonomy is mainly influenced by:
a. environmental factors, that cause
higher energy requirements:
– cutting trees and branches that are too thick.
b. operator behaviour that should be avoided:
– switching the machine on and off
frequently whilst working;
– adopting a cutting technique
that is unsuitable for the work to
be performed (par. 6.4).
To optimise battery power reserve it is always
recommended to:
• cut wood when dry;
• do not force the tool.
If the need arises to use the machine for sessions
which exceed the capability of a standard battery,
it is possible to:
• purchase a second standard battery to
immediately replace the discharged battery,
without
compromising
operations.
7.2.2 Battery removal and recharging
1. Press the locking button located in the battery
(Fig. 8 A)
2. remove the battery from the machine (Fig.8
B);
3. Insert the battery in its housing of the battery
charger (Fig.9);
4. Connect the battery charger to a power socket
(Fig. 9 B), with a voltage corresponding to that
indicated on the plate.
5. Proceed with complete recharging, following
the instructions contained in the battery /
charger booklet.
NOTE   The  battery  is  equipped  with  a  guard 
that inhibits recharging if the environmental
temperature is not between 4 and +40 °C.
NOTE   The  battery  can  be  recharged  at  any 
time, even partially, with no risk of damaging it.