Descargar Imprimir esta página

Ditel JR-P Manual Tecnico página 62

Indicador universal para entrada proceso y temperatura
Ocultar thumbs Ver también para JR-P:

Publicidad

Idiomas disponibles

Idiomas disponibles

SETPOINTS CONFIGURATION
Setpoints configuration
SEtP
SEt1
SEt2
Hi
Lo
no
nc
dLy
HyS
00.0
00.00
If 2RE output option card is uninstalled, the instrument keeps setpoints last configuration in memory, though it can
not be visualized.
Thanks to this feature there will be no need to reconfigure relays setting when 2RE output option is again installed
if the same configuration is required.
SERIE KOSMOS
The third menu "SEtP" only appears when two relays output card is
installed. For further details on function modes please refer to the
corresponding OUTPUT OPTION part later on this manual.
Programming steps are equal for both relays on each "SEt1" and
"SEt2" submenus. The parameters to be configured are the following:
SETPOINT VALUE:
00.00:
Value entering in counts within available model display range.
(Is not possible to change decimal point position, which is
the previously defined in display configuration menu).
ACTIVATING MODE:
Hi:
High level relay activation.
Lo:
Low level relay activation.
RESTING CONTACTS STATE:
no:
Normally open contact.
nc:
Normally closed contact.
TIME DELAY AND HYSTERESIS:
dLy:
Programmable delay from 0 to 99.9s.
HyS:
Hysteresis in counts within available model display range.
www.ditel.es
JR-P / JR20-P
62

Publicidad

loading

Este manual también es adecuado para:

Jr20-pJunior-pJunior20-p