Replacing LED Lighting
To replace any of the LEDs, please contact
the nearest Authorised Service Centre.
Note: The numbers and location of the
LED strips may change according to
the model.
If product equipped with LED lamp
This product contains a light source of
energy efficiency class <E>.
If product equipped with LED Strip(s) or
LED card(s)
This product contains a light source of
energy efficiency class <F>.
6 SHIPMENT AND
REPOSITIONING
6.1 Transportation and Changing
Positioning
• The original packaging and foam may be
kept for re-transportation (optional).
• Fasten your appliance with thick
packaging, bands or strong cords and
follow the instructions for transportation
on the packaging.
• Remove all movable parts or fix them
into the appliance against shocks
using bands when re-positioning or
transporting.
Always carry your appliance in the
upright position.
7 BEFORE CALLING AFTER-
SALES SERVICE
Errors
Your appliance will warn you if the
temperature(s) is/are at improper levels
or if a problem occurs with the appliance.
SR Alarm indicator (
control panel.
ERROR TYPE
MEANING
WHY
WHAT TO DO
If you are experiencing a problem with
your appliance, please check the following
before contacting the after-sales service.
Your appliance is not operating
Check if:
• There is power
• The plug is correctly placed in the socket
• The plug fuse or the mains fuse has
blown
• The socket is defective. To check this,
plug another working appliance into the
same socket.
The appliance performs poorly
Check if:
• The appliance is overloaded
• The appliance door is closed properly
• There is any dust on the condenser
• There is enough space near the rear and
side walls.
Your appliance is operating noisily
Normal noises
Cracking noise occurs:
• During automatic defrosting
EN - 73
) is displayed in the
( ! ) SR alarm indicator
"Failure" Warning
There is/are some part(s) out
of order or there is a failure in
the cooling process.
The product is plugged for the
first time or a long-time power
interruption for 1 hour.
Check the door is open or
not and check if the product
working 1 hour. If the door is
not open and the product had
worked 1 hour, call service
for assistance as soon as
possible.