GROUNDING
THE
GENERATOR
The National Electric Code requires the frame and
external electrically conductive parts of the generator be
properly connected to approved earth ground. Local
electrical codes may also require proper grounding of the
unit. For this purpose, a grounding fastener (Figure 2) is
provided on the cradle.
Fastener
I.
Turn the fuel valveto the "On"
position (Figure 3).
2.
Place the choke lever in the "Choke"
position
(Figure 4).
Generally, connecting a No. 12AWG (American Wire
Gauge) stranded copper wire to the grounding wing nut
and to an earth-driven copper or brass grounding rod
(electrode) provides adequate protection against electrical
shock. However, local codes may vary widely. Consult with
a local electrician for grounding requirements in your area.
Be sure to keep the ground wire attached while you
connect the electrode.
Properly grounding the generator helps prevent electrical
shock if a ground fault condition exists in the generator or
in connected electrical devices, especiallywhen the unit is
equipped with a wheel kit. Proper grounding also helps
dissipate static electricity, which often builds up in
ungroundeddevices.
OPERATING
THE
GENERATOR
_
CAUTION!
NEVER start or stop unit with
electrical loads connected AND with the connected
devices turned ON.
Starting
the Engine
Disconnect all electrical loadsfrom the generator. Use the
following start instructionsteps by numerical order:
3.
Set the rocker switch to "On" position (Figure 5).
4.
Grasp the recoil handle and pull slowly until slight
resistance is felt.Then pull rapidly to start engine.
5.
Move choke lever to "Run" position a short distance
at a time over several seconds in warm weather or
minutes in cold weather. Let engine run smoothly
before each change.Operate with choke in "Run"
position.
NOTE: If engine still fails to start after 3 pulls, check for
proper oil level in crankcase.This unit is equipped with a
low oil device that will not allow the engine to start. See
engine manual.
Refer to the engine owner's manual
for complete
starting
instructions.