J WARNING:
Risk of electrocution.
High-voltage
circuits, both AC and DC, J
are very dangerous and should be measured with great care.
I
1. ALWAYS turn the function switch to the OFF position when the meter is
not in use.
2. If "1" appears in the display during a measurement,
the value exceeds
the range you have selected. Change to a higher range.
NOTE: On some low AC and DC voltage ranges, with the test leads not
connected to a device, the display may show a random, changing
reading. This is normal and is caused by the high-input sensitivity.
The reading will stabilize and give a proper measurement
when
connected to a circuit.
DC VOLTAGE MEASUREMENTS
J
AUTION:
Do not measure DC voltages if a motor on the circuit is
being switched ON or OFF. Large voltage surges may occur that can
damage the meter.
1. Set the function switch to the highest V DC position.
2.
Insert the black test lead banana plug into the
negative (COM) jack.
Insert the red test lead banana plug into the positive
(V) jack.
3. Touch the black test probe tip to the negative side of
the circuit.
Touch the red test probe tip to the positive side of the
circuit.
4.
Read the voltage in the display. Reset the function
switch to successively
lower V DC positions to obtain a higher
resolution reading. The display will indicate the proper decimal point
and value. If the polarity is reversed, the display will show (-) minus
before the value.