Programming (continued)
WIRING
DEVICE
TYPE
Single
Button Wall
Controller
(Wired)
B2 (continued)
myQ
Smart
®
Facility
Access
WIRING
DEVICE
TYPE
C2
Momentary
contact to
open and stop
with constant
pressure to
close (wired
devices ONLY),
Front panel
open override
buttons
plus wiring for
(membrane)
sensing device
and 3-Button
to reverse.
Wall
Open Mid-Stop
Controller
available with
this mode type.
Compatible
with 3-Button
Station and
Single-Button
Station
ACTION
STATE
Operator at OPEN limit
Operator at CLOSE limit
Door opening
Button is pressed
Door closing
Door at Open Mid-Stop
Door stopped during the open cycle
Door stopped during the close cycle
Button is held
Door Opening
(constant pressure)
Operator at OPEN limit
Operator at CLOSE limit
Door opening
Open is pressed
Door closing
Door at Open Mid-Stop
Door stopped during open or close cycle Door opens to the OPEN limit or Mid-Stop
Operator at OPEN limit
Operator at CLOSE limit
Door opening
Close is pressed:
Door closing
Door at Open Mid-Stop
Door stopped during open or close cycle Door closes to the CLOSE limit
ACTION
STATE
Operator at OPEN limit
Operator at CLOSE limit
Door opening
OPEN button
is pressed
Door closing
momentarily
Door at Open Mid-Stop
Door stopped during open or close cycle
Operator at OPEN limit
Operator at CLOSE limit
Door opening
CLOSE button
is pressed
Door closing
momentarily
Door at Open Mid-Stop
Door stopped during open or close cycle
Operator at OPEN limit
Operator at CLOSE limit
STOP button
Door opening
is pressed
Door closing
momentarily
Door at Open Mid-Stop
Door stopped during open or close cycle No change in state
Operator at OPEN limit
Operator at CLOSE limit
Door opening
OPEN button is held
(constant pressure)
Door closing
Door at Open Mid-Stop
Door stopped during open or close cycle
Operator at OPEN limit
Operator at CLOSE limit
CLOSE button is
Door opening
held (constant
Door closing
pressure)
Door at Open Mid-Stop
Door stopped during open or close cycle Door closes to the CLOSE limit
35
RESPONSE
Door closes to the CLOSE limit
Door opens to the OPEN limit or Mid-Stop
Door stops
Door will auto reverse to OPEN limit or
Mid-Stop
Door opens to the OPEN limit
Door closes to the CLOSE limit
Door opens to the OPEN limit or Mid-Stop
No change in state (bypasses Mid-Stop)
No change in state
Door opens to the OPEN limit or Mid-Stop
No change in state
Door will auto reverse to OPEN limit or
Mid-Stop
Door opens to the OPEN limit
Door closes to the CLOSE limit
No change in state
No change in state
No change in state
Door closes to the CLOSE limit
RESPONSE
No change in state
Door opens to the OPEN limit or Mid-
Stop
No change in state
Door will auto reverse to OPEN limit or
Mid-Stop
Door opens to the OPEN limit
Door opens to the OPEN limit or Mid-
Stop
Door closes and stops when button is
released
No change in state
No change in state
No change in state
Door closes and stops when button is
released
Door closes and stops when button is
released
No change in state
No change in state
Door stops
Door stops
No change in state
No change in state
Door opens to OPEN limit (bypasses
Mid-Stop)
No change in state (bypasses Mid-Stop)
Door will auto reverse to OPEN limit
(bypasses Mid-Stop)
Door opens to the OPEN limit
Door opens to the OPEN limit (bypasses
Mid-Stop)
Door closes to the CLOSE limit
No change in state
No change in state
No change in state
Door closes to the CLOSE limit