1.1
General information .................. 3
1.2
Scope of delivery ...................... 3
1.3
Conventional use ...................... 3
1.4
Technical data .......................... 3
1.5
Components............................. 4
1.6
Maintenance............................. 4
1.7
Compressor inspections ............. 4
1.8
EC Declaration of Conformity ...... 4
The specified illustrations appear at the be-
ginning of the Operating Instructions.
1.1
General information
Observe the safety instructions!
Read the Instruction Manual!
Note: Read and memorise part 2 of the in-
struction manual!
1.4
Technical data
Suction capacity
Filling capacity
Voltage
Electric protection, delayed-action
Motor output
Max. operating speed
Compression final pressure
Switch-on pressure
Vessel capacity
Maximum permissible working overpressure of vessel
L
Sound pressure level at distance of 4 m
PA4
Overall dimensions: width x depth x height
Weight
Max. number of switching cycles
Operation/Downtime ratio
Min. distance to wall
Ambient temperature
SEM 100-8-6 W-oilfree
Subject to technical modifications. Illustra-
tions may deviate from the original.
1.2
Scope of delivery
– Compressor with instruction manual
– Documents accompanying compressed air
vessel
1.3
Conventional use
The compressor is designed for generating
and storing compressed air only. Com-
pressed air is only suitable for compressed
air tools/devices/machines.
The compressor has no sound-power certifi-
cation as specified in 2000/14/EC and cannot
be used out of doors.
Any other type of use is considered contrary
to the intended use.
370 x 200 x 415 mm
GB
95 l/min
50 l/min
230 V
6 A
0,55 kW
1420 rpm
8 bar
6 bar
6 l
8 bar
64 dB(A)
14 kg
10 1/h
60:40 --
40 cm
5-35 °C
I/3

Publicidad

loading

Este manual también es adecuado para:

A 333 002