Edirol UR-80 Manual Del Usuario página 383

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Sender Model Name
Transmitted when entering V-LINK mode.
]Status
Data byte
F0H
41H,10H,00H,51H,12H,
10H,71H,00H,45H,44H,49H,52H,4FH,4CH,
20H,55H, 52H, 2DH, 38H, 30H, 00H, 64H
Byte
Explanation
F0H
Exclusive status
41H
ID number (Roland)
10H
Device ID (For the UR-80, fixed at 10H)
00H 51H
Model ID (V-LINK)
12H
Command ID (DT1)
Address
10H 71H 00H
45H 44H 49H
Model name (EDIROL UR-80)
52H 4FH 4CH
:
20H 55H 52H 2DH :
38HH 30H 00H
:
64H
Checksum
F7H
EOX (End of Exclusive)
Data Set 1 DT1 (12H)
Transmitted when you execute Bulk TX in the Bulk mode.
Status
Data byte
F0H
41H, 10H, 00H, 68H, 12H,
aaH, ddH, ...eeH, sum
Byte
Explanation
F0H
Exclusive status
41H
ID number (Roland)
10H
Device ID
00H
Model ID #1 (UR-80)
68H
Model ID #2 (UR-80)
12H
Command ID (RQ1)
aaH
Address
ddH
Data
:
:
:
eeH
Data
sum
Checksum
F7H
EOX (End of Exclusive)
* The amount of data that can be transmitted at once is fixed for each type of data.
Data that does not have the specified starting address and data size will not be
received. Refer to the explanation in 3. Bulk Dump.
* There must be an interval of at least 40 ms between each exclusive message that
is sent.
3. Bulk dump
Bulk dump allows a large amount of data to be transferred in a single operation.
Status
For example, this can be used to store all settings of a device into a computer or
F7H
sequencer.
Parameter Dump
Parameter Dump Request
This command requests a device to transmit all of the memory set data from its
internal memory. The "Data Request 1 (RQ1)" format is used.
Status
F0H
aa =
Memory set number
0:
1–7
This is transmitted when a Parameter Dump Request is received. The bulk dump is
divided into two or more exclusive messages for transmission.
Address
01 00 00 00
01 10 00 00 - 01 11 07 00
Status
* You must leave an interval of at least 40 ms between each exclusive message.
F7H
* Please be aware that if you modify the data dumped from the UR-80 by
changing the order in which the exclusive messages are transmitted, by
inserting other messages between the system exclusive messages, or by
speeding up the timing of the transmission, the data may not be set correctly
when the UR-80 receives it.
Data byte
41H,10H,00H,68H, 11H, 00H, 00H, 00H, aaH, Sum
PRESET
USR1–7
Explanation
Current memory
Common parameters
Current memory
Common parameters
MIDI implementation
Status
F7H
Number of packets
1
136
383

Publicidad

Tabla de contenido
loading

Tabla de contenido